MAGNET POWER SUPPLY SYSTEM 7000
37
DANFYSIK A/S - DK 4040 JYLLINGE - DENMARK.
4.3.16
Summed Current Error
The measured Error signal from U303A is converted into a proportional current, U913A and
U920B.
Each Slave unit feeds this current to the parallel interface cable.
The Master unit converts the total current in the parallel cable into a voltage. The number of
units in parallel, U913B, U916 and U918 then scales this voltage. Hereby 2% current error is
equal to ±10V. The scaling is controlled by a 3-bit code coming from the Front Panel.
4.3.17
Analog measurements
This block processes the Analog measurements.
A high input impedance low drift differential amplifier U301B gives excellent stable
measurement of the voltage across the burden resistor (1V).