4.4.8
Output filter
The power transformer current is rectified and filtered by L301, C304 and C314.
High-speed diodes from International Rectifier decreases the switching loses in the diodes and the
reflected reverse recovery current in the switch FET’s in the primary.
The storage choke L301 is wound on an ETD 49-coil form. Thin parallel enamelled copper wires
make the windings in the choke. Thin wires reduce the power loss to a minimum due to the high
frequency skin depth effect.