MAGNET POWER SUPPLY SYSTEM 9100
28
DANFYSIK A/S - DENMARK.
LINE FUNCTION PROTOCOL SETUP
(Esc<LINE)
SW3 FOR LOCAL LINE
SW3 FOR REMOTE LINE
O
N
O
N
1
2
3
4
1
2
3
4
5
2
The “LINE FUNCTION PROTOCOL SETUP” is for setting up serial line protocols.
Parameters:
SW4
„OK‟ ANSWER MODE
DISABLED
ENABLED
RS 485 LINE TURN AROUND
DISABLED
ENABLED
RS 485 LINE TURN AROUND
DISABLED
ENABLED
RS 485 COMMUNICATION
DISABLED
ENABLED
NOT USED
DISABLED
ENABLED
XON/XOFF PROTOCOL
DISABLED
ENABLED
NOT USED
BOOT CHARACTER
SEND “FF” Hex
SEND “R”
O
N
1
2
3
4
5
6
7
8
DISABLED
ENABLED
Default setting after “COLD BOOT”
Remote Line: RS485 Communication:
Disabled
(=0)
RS485 Line turn around time:
Disabled Line turn around set bit 0
RS485 Line turn around time:
Disabled Line turn around set bit 1
OK Answer mode:
Disabled
BOOT character:
"FF" / "R"
NU
Disabled
XON/XOFF Protocol:
Disabled
NU
Disabled
Local Line: RS485 Communication:
Disabled
(=1)
RS485 Line turn around time:
Disabled Line turn around set bit 0
RS485 Line turn around time:
Disabled Line turn around set bit 1
OK Answer mode:
Disabled
BOOT character:
"FF" / "R"
NU
Disabled
XON/XOFF Protocol:
Disabled
NU
Disabled
Line turn around set bit:
2, 3:
0, 0
Delay = 0
2, 3:
1, 0
Delay = 1ms approx.
2, 3:
0, 1
Delay = 2ms approx.
2, 3:
1, 1
Delay = 3ms approx.
The line turn around time setting includes RS422 as well.