15
www.Daniel.com
USER MANUAL
2
Operating conditions and
specifications
2.1
Operating conditions for the 707 control valve
Table 2-1: Operating conditions for the control valve
Condition type
Description
Fluid phase
Liquid
Process temperature
-29 °C to 66 °C (-20 °F to 150 °F)
Fluid velocity
Operational recommended flow velocity up to 30 ft/sec,
beyond this point will result in a high pressure drop and
increased wear.
Fluid(s) controlled
•
Low/Medium viscosity crude oils and condensates
•
Refined products and intermediates (ie: gasoline, diesel,
kerosene, light fuel oils, jet fuel, LPG, butanes, naphtha,
alkylate, reformate, straight run gasoline, cat-cracked
gasoline)
•
Petrochemicals (ie: benzene, toluene, xylenes, cumene,
olefins, pyrolysis gasoline)
•
Natural gas liquids
Viscosity limits
Maximum valve viscosity is 8800 Cst
Differential pressure
The maximum allowable differential pressure across a control
valve is 6894 kPa (1,000 psi). Consult factory for location of
first shut down valve.
Sizes (NPS)
2, 3, 4
Pressure class (ANSI)
150, 300, 600
Maximum safe working
temperature range
•
-26 °C to 204 °C (15 °F to 400 °F)
•
Using Viton
®
O-rings
•
Consult the factory for other safe working temperatures
Maximum safe working pressure
Flange connections/Ratings (ANSI) for valve sizes 2"- 4":
•
Class 150 MWP at 100 °F: 285 psi
•
Class 300 MWP at 100 °F: 740 psi
•
Class 600 MWP at 100 °F: 1480 psi
* MWP: Maximum Working Pressure
User manual
Operating conditions and specifications
DAN-20064957
August 2019
User manual
19