CONVERSION TO ANOTHER GAS TYPE
•
If the gas appliance is to be used with another gas type e.g. either Propane Gas or Natural
Gas, it must be converted by an Authorised Person. Contact Daniela Appliances or their
authorised agent for information and parts.
NATURAL GAS
PROPANE GAS
Injector
Diameter
MJ/h
Gas
Pressure
Injector
Diameter
MJ/h
Gas
Pressure
Wok Burner
1.70
13
1.0 kPa
0.98
13
2.75 kPa
Large Burner
1.40
10
1.0 kPa
0.90
10.5
2.75 kPa
Medium Burner 1.10
6.5
1.0 kPa
0.70
6.5
2.75 kPa
Small Burner
0.90
4.2
1.0 kPa
0.55
3.7
2.75 kPa
***64
30.2 MJ/h
29.7 MJ/h
***75, ***95
40.2 MJ/h
40.2 MJ/h
The table above shows the appropriate injector sizes for either Natural Gas or LPG (Propane)
IMPORTANT
! The conversion work must be carried out by a registered gas fitter and in
accordance with the current standards.
WARNING:
Always isolate the cooktop from the electricity supply before changing the injectors
and/or adjusting the minimum flow of the burners.
•
Remove the pan-stands, burners and flame spreaders (A).
•
Unscrew the injector (B) and replace it with the stipulated
injector for the new gas supply (see table on page 15).
•
Reassemble all the burners carefully; in particular you
should make sure that the flame spreader is correctly
placed on the burner.
IMPORTANT!
The minimum flow adjustment process
must be completed before the appliance is next used.