After conversion check the GAS PRESSURE and IGNITER OPERATION for the burners.
If the hotplate cooker cannot be adjusted to perform correctly, or if there is excessive
flame discolouration, yellow tipping or excessive noise, contact Daniela Appliances or
their authorised service agent for advice.
Please also ensure that the duplicate data plate supplied be attached to the appliance
or in an easily accessible place such as an adjacent cupboard for future reference.
MINIMUM FLOW ADJUSTMENT FOR COOKTOP GAS TAPS
IMPORTANT
! All work must be carried out by a registered gas fitter and in accordance with the
current standards.
WARNING:
Always isolate the cooktop from the electricity and gas supply before changing the
injectors and/or adjusting the minimum flow of the burners.
•
Switch the burner on and set the knob at the minimum position.
•
Remove the knob from the tap and place a small bladed screwdriver in the centre of the tap shaft.
•
Unscrew the adjusting screw, in order to increase the gas flow or tighten the adjusting screw
to decrease the gas flow.
•
The correct adjustment is obtained when the flame has a length of about 3-4mm.
•
For ULP gas, the adjusting screw must be tightly screwed in.
•
Refit the control knob.
•
Make sure that the flame does not go out by quickly turning
from maximum flow to minimum flow. lf it does then remove
the control knob and make further adjustments to the gas flow,
testing it again once the adjustment has been made.
•
Repeat this process for each one of the gas taps.
•
When converting from Narural Gas to ULP gas ensure that the NG
regulator is removed and replaced with the Test Point Assembly. A gas regulator suitable for a
supply pressure of 2.75kPa should be at the inlet to the appliance. Replace the old data plate
with one which is suitable for the type of gas for which the appliance has been regulated.
IMPORTANT
! Where this appliance is installed in marine craft or in caravans, it shall not be used as
a space heater.
TROUBLESHOOTING HOTPLATES
•
Users are not allowed to perform any maintenance operations on any parts of this appliance.
Maintenance must be carried out exclusively by authorized technical service personnel.
•
To access burners, injectors, valves etc; disconnect gas and power supply from appliance.
Ensure appliance is cool before removing trivets, burners etc.