PAG E 7
INSTALLATION & USE
OPERATION OF CONTROLS
•
The hood is operated using the touch control.
•
The on/off switch turns the hood on and off.
•
The light switch turns the lamps on and off.
The blower switch turns the blower on to three speed settings:
1.
Low speed
2.
Medium speed
3.
High speed
GREASE FILTERS
The grease filters should be cleaned frequently. Use a warm detergent solution.
The stainless-steel filters are washable.
INSTALLATION OF THE DUCT WORK
NOTE: Please ensure that these filters are completely dry before using.
CAUTION:
To reduce the risk of noise or fire, use metal ductwork is preferred.
1.
Decide where the ductwork will run between the hood and the outside.
2.
A straight, short duct run will allow the hood to perform most efficiently.
3.
Long duct runs, elbows, and transitions will reduce the performance of the hood. Use as few
of them as possible. Larger ducting may be required for best performance with longer duct
runs. You will lose 100m
3
of suction for every elbow in your ducting.
4.
The air must not be discharge into a flue that is used for exhausting fumes from appliances
burning gas or other fuels” “Regulations concerning the discharge of air have to be fulfilled.
5.
Install wall cap. Connect round metal ductwork to cap and work back towards
hood location. Use duct tape to seal the joints between duct work sections.
low mid high light on/off