18
o
Prolonged intensive use of the appliance may call for additional
ventilation, either by the opening of a window, or by increasing
the level of the mechanical ventilation device (where present).
o
This hob is not fitted with a device for discharging the products
of combustion. Ensure that the ventilation rules and regulations
are followed.
o
The walls behind and near the hob should be resistant to heat,
steam and condensation.
o
Remember that the quantity of air necessary for combustion
must never be less than 2m³/h for each kW of power (see total
power in kW on the appliance rating plate).
Dual gas regulator valve introduction
Product Features:
o
This product has a low-pressure pipeline regulator valve, built-in
voltage regulator for gas products.
Gas connection
Install in accordance with relevant gas standards and/or codes of practice applicable.
Connect the elbow fitting to the appliance gas manifold connection, and check that
seals between the elbow and manifold connection are in place and in good condition.
For NG or LPG you need to install the regulator ( picture below) supplied with the
appliance. There regulator has a test point to enable an anthourised licenced
plumber / gasfitter to check for gas leaks after the cooktops installation.
Screw LPG setting
Screw NG setting
Gas pressure test point