22
o
Reassemble all burners carefully; in particular you should make
sure that the flame spreader is correctly placed on the burner.
o
IMPORTANT:
The minimum flow adjustment process must be
completed before the appliance is used.
Minimum flow adjustment for hob gas taps
All work must be carried out by a licensed
gas fitter.
IMPORTANT: Always isolate the hob from the electricity
supply before changing the injectors and/or adjusting the
minimum flow of the burners.
o
Remove all the pan supports,
caps,
flame
spreaders
and
knobs.
o
Unscrew the screws of the
panel, then remove the panel.
o
Install cap, flame spreader,
knob of the burner. Switch the
burner on and set the knob at
the minimum position.
KIND
OF GAS
NOZZLE
mm/100
BURNERS
POWER (MJ/h)
Maximum
Minimum
Natural
180
149
116
85
Wok
Large
Medium
Small
14.4
10.8
6.5
3.8
7.0
5.4
3.24
1.8
L.P.G.
Butane
Propane
107
93
72
53
Wok
Large
Medium
Small
15.0
11.0
7.0
4.0
7.0
5.4
3.24
1.8