FOR TECHNICAL QUESTIONS, CALL (877)432-6627
25
2. Route the cord up through the power side column using the unused slot then up and across the top
tough through the hole on the microswitch box. (See figure 25 & 26)
When routing the microswitch cable it must be run through the clips in the column and top trough. Failure
to do so can cause damage to the lift or vehicles.
STEP 14
(Wiring the Power Unit)
1. The standard power unit for your lift is 220 volt, 60HZ,
single phase.
ALL WIRING MUST BE PERFORMED
BY A CERTIFIED ELECTRICIAN ONLY.
2.
SEE WIRING INSTRUCTIONS AFFIXED TO MOTOR
FOR PROPER WIRING INSTRUCTIONS
.
IMPORTANT INSTALLATION NOTES
DO NOT PERFORM ANY MAINTENANCE OR IN-
STALLATION OF ANY COMPONENTS WITH OUT
FIRST ENSURING THAT ELECTRICAL POWER HAS
BEEN DISCONNECTED AT THE SOURCE OR PANEL
AND CANNOT BE RE ENERGIZED UNTIL ALL MAIN-
TENANCE AND / OR INSTALLATION PROCEDURES
ARE COMPLETED.
NEVER
operate the motor on line voltage less than
208V. Motor damage may occur which is not covered
under warranty.
DO NOT
run power unit with no oil. Damage to pump can occur.
The power unit must be kept dry. Damage to power unit caused by water or other liquids such as de-
tergents, acid etc. , is not covered under warranty.
Improper electrical hookup can damage the motor and will not be covered under warranty.
CAUTION
Fig: 24
Fig: 25
Cable clips
Fig: 26
Safety cover
is hidden for
clarity.
DANGER