DLR-6/6P Low-Rise Scissor Lifts
21
P/N 5900254 — Rev. A — September 2020
⚠
CAUTION
Do not let contaminants get into the Lift’s Hydraulic System. Only use Liquid Thread
Sealant where the instructions say it can be used. Do
not
use Thread Seal Tape.
To connect the Hydraulic Hose
:
1.
Remove the Shipping Plug from one of the two Hydraulic Power Out ports on the Power Unit.
The Hydraulic Power Ports are commonly labeled P1/P2 on the Power Unit.
2.
For the DLR-6, attach the 06 ORB connector of the Elbow Hydraulic Fitting (06 ORB – 04 JIC) to
the Hydraulic Power Out Port.
For the DLR-6
P
, attach the Male Quick-Connect Fitting to the Hydraulic Power Out Port.
3.
For the DLR-6, attach one end of the Hydraulic Hose to the 04 JIC end of the Elbow Hydraulic
Fitting you just attached to the Power Unit.
For the DLR-6
P
, attach the Female Quick-Connect Fitting to the NPT end of the Hydraulic Hose,
then attach it to the Male Quick-Connect Fitting you just attached to the Power Unit.
4.
Route the other end of the Hydraulic Hose from the Power Unit, under the Fixed Ramp, and to the
Hydraulic Cylinder.
5.
Remove the Shipping Plug from the plug at the bottom of the Hydraulic Cylinder.
6.
Attach the 04 NPT end of the Straight Hydraulic Fitting (04 JIC – 04 NPT) to the port on the
Hydraulic Cylinder, then connect the Hydraulic Hose to the Straight Fitting.
If you like, you can use liquid thread sealant on the NPT connector to help prevent leaks. Do not
use thread seal tape.
7.
Use appropriate tools to securely tighten all of the connections.
Add Hydraulic Fluid
The Hydraulic Fluid Reservoir on the Power Unit must be filled with Hydraulic Fluid or automatic
transmission fluid
before
you begin normal operation of the Lift.
The Hydraulic Fluid Reservoir holds approximately
1.5 gallons / 5.5 liters
.
Approved fluids are any general purpose ISO-32, ISO-46, or ISO-68 Hydraulic Fluid, approved
automatic transmission fluids such as Dexron III, Dexron VI, Mercon V, Mercon LV, or any synthetic
multi-Vehicle automatic transmission fluid.
Take care to
keep contaminants out
of the Hydraulic Fluid Reservoir.
⚠
WARNING
Do not run your Power Unit without Hydraulic Fluid; you will damage it.
Summary of Contents for DLR-6
Page 32: ...DLR 6 6P Low Rise Scissor Lifts 32 P N 5900254 Rev A September 2020 Labels ...
Page 33: ...DLR 6 6P Low Rise Scissor Lifts 33 P N 5900254 Rev A September 2020 ...
Page 34: ...DLR 6 6P Low Rise Scissor Lifts 34 P N 5900254 Rev A September 2020 Parts Diagrams ...
Page 35: ...DLR 6 6P Low Rise Scissor Lifts 35 P N 5900254 Rev A September 2020 ...
Page 36: ...DLR 6 6P Low Rise Scissor Lifts 36 P N 5900254 Rev A September 2020 ...
Page 37: ...DLR 6 6P Low Rise Scissor Lifts 37 P N 5900254 Rev A September 2020 ...
Page 38: ...DLR 6 6P Low Rise Scissor Lifts 38 P N 5900254 Rev A September 2020 ...