background image

Dansensor A/S

COPYRIGHT ©

PBI-320297-B 02/2014

CheckPoint O

2

EN

User Guide

15

Spare parts and accessories

Consumables

200717

Kit, needle pen incl. hose and fittings, Ser. Cpl.

200719

Kit, batteries, 4 pcs., type AA, Ser. Cpl.

200726

Kit, rechargeable battery pack, CheckPoint, Ser. Cpl.

220121

Needle kit, 0.5 mm (10 pcs.), Ser. Cpl.

280205

Needle kit, 0.5 mm (100 pcs.), Ser. Cpl.

280167

Needle kit, blunt (10 pcs.), Ser. Cpl.

310335

Filter, sample gas, 0.2μ, water trap (10 pcs.), Ser.Cpl.

Spare parts

200720

Pump, CheckPoint, Ser. Cpl.

200721

Kit, hoses, internal, Ser. Cpl.

200725

Kit, fittings, CheckPoint, Ser. Cpl.

330016

Sensor, O

2

 EC, Ser. Cpl.

330021

Kit, adapter, Ø3.1/Ø2.2, Sensor O

2

 EC Ser. Cpl.

330034

Hose, silicone, Ø4/7mm (10 pcs. x 70mm) Ser. Cpl.

330035

Tape, glazing (10 pcs. x 70mm) Ser. Cpl.

Optional equipment

310341

Adapter, AC/DC 7,5VDC, Multi, Ser. Cpl.

200678

Option, arm strap, CheckPoint

Summary of Contents for CheckPoint O2

Page 1: ...PBI 320297 B 02 2014 CheckPoint O2 DE DA SV RU FR ES IT EN PT...

Page 2: ...S COPYRIGHT PBI 320297 B 02 2014 CheckPoint O 2 Distributor Sales Service and Calibration Topac Inc 231 CJC Highway Cohasset MA 02025 Tel 781 7408778 Fax781 740 8779 Email sales topac com internet ww...

Page 3: ...2 CheckPoint O2 PBI 320297 B 02 2014 COPYRIGHT Dansensor A S 7 13 5 14 6 4 1 3 2 7 8 8 9 11 12 10...

Page 4: ...condensing O2 Sensor Electrochemical Range 0 100 Resolution 0 1 Accuracy 0 25 abs 2 rel Temperature compensation 2 rel steady state Response time T95 15 sec Expected sensor lifetime 9 months Recommen...

Page 5: ...10 Brugerguide DA CheckPoint O2 PBI 320297 B 02 2014 COPYRIGHT Dansensor A S NOTER...

Page 6: ...second measuring period is started Reduced measuring time The measuring period can be reduced by pressing while measuring is in progress Memory function CheckPoint remembers up to 10 measurements incl...

Page 7: ...n performing consecutive measurements in areas with large differences in the O2 concentrations the device will reach 95 of the true value during the first measurement 15 sec Example See illustration b...

Page 8: ...During calibration the display alternately shows CAL and 20 9 for 45 seconds CheckPoint has now been calibrated Stop calibration Press to interrupt the calibration process External power supply charg...

Page 9: ...t the needle retainer 9 in the opposite side and press it down until flush with the side plate 6 Test control Switch on the CheckPoint and start measuring with atmospheric air 20 9 Block the gas inlet...

Page 10: ...205 Needle kit 0 5 mm 100 pcs Ser Cpl 280167 Needle kit blunt 10 pcs Ser Cpl 310335 Filter sample gas 0 2 water trap 10 pcs Ser Cpl Spare parts 200720 Pump CheckPoint Ser Cpl 200721 Kit hoses internal...

Page 11: ...16 User Guide EN CheckPoint O2 PBI 320297 B 02 2014 COPYRIGHT Dansensor A S NOTES...