37
37
37
37
M (Depending on the model of PTZ camera)
If selected, the OSD menu of PTZ camera is imported and shown on the DVR monitor and hence
user can make full PTZ setting.
PROTOCOL
Select the proper protocol of the connected PTZ camera.
ADDRESS
Set the P/T/Z driver address of the connected camera.
Check the below items for proper P/T/Z operation.
Check if the protocol of the connected PTZ camera is correct.
Check if the communication setting including baud rate of the connected PTZ camera is in
accordance with the assigned value for that P/T/Z protocol.
Check if the address of the connected PTZ camera is correct.
Check if wiring to P/T/Z controllers is correct.
Procedure How to setup PTZ camera with Pelco-D protocol (example)
1) Make sure of serial communication with the PTZ camera through RS-485 port.
2) Select “Pelco-D” in the protocol list, and set address.
3) Click “Save” button to confirm this configuration.
PRESET
The system supports the number of preset from 1 to 255.
But it can be restricted by the number that PTZ camera supports.
BAUD RATE
User can select the baud rate level from 2,400bps up to 57,600bps.
Summary of Contents for DLW5400
Page 3: ......