background image

P

AGE

 20

44210/49210-0798 <90-00025>

FCC REQUIRED INFORMATION

T

he following are requirements of Part 68 of FCC Rules:

1.

The installer of this equipment is responsible for notifying the tele-
phone company that it is being connected or disconnected.

2.

This equipment is not to be connected to party lines or coin tele-
phone service.

3.

The telephone company has the right to temporarily discontinue
service (Section 68.108) and to change facilities and services which
may affect the operation of this equipment. Adequate written no-
tice will be provided to the user to maintain uninterrupted service
(Section 68.110B).

4.

In case of trouble, contact the manufacturer’s authorized agent.

5.

When the installation of this device requires connection or changes
to the internal wiring of registered telephones or other registered
devices, such changes and connections can be made only by the
registered grantee or authorized agents, equipment manufacturers,
registered telephone refurbishers, telephone companies, and those
qualified for the installation of KN and PN systems under Section
68.215 of the rules. The installer of this equipment is advised, in
the interest of safety, that the host equipment be disconnected from
all power sources and the telephone network when the installation
is being made.

6.

Installation of this equipment as an adjunct can be made only with
permission of the owner of the host equipment.

FCC required information pertaining to this module:

Registration Number:  DPH622-60575-MD-E

Summary of Contents for 44210

Page 1: ...nical Reference TR NWT 000870 Copyright 1998 by Dantel Inc Dantel is a registered trademark of Dantel Inc ISO 9001 Registered Printed in the U S A INSTALLATION OPERATION MANUAL 44210 49210 0798 90 000...

Page 2: ...ly provides an interface to two telephone lines a primary and a backup The 44210 is a plug in module that fits into any 400 type or similiar equipment housing The front panel has status indicat ing LE...

Page 3: ...44 LINE SELECT 2 RING TIP TIP RING 2 WIRE LINE 1 2 WIRE LINE 1 TO RJ11 TO RJ11 41 42 23 24 50 AUDIO MONITOR 40 OFF HOOK 21 TO 56 VDC GND RCVRs TTL Interface DRVRs RCVRs RS 232 Interface DRVRs RCVRs R...

Page 4: ...tile memory for the microprocessor programming Address Latch and Decoder The address latch and decoder reads the address switch setting and programs the microprocessor to recognize that address The la...

Page 5: ...ermina tion straps must be in the OFF position Front panel LEDs are provided on the module to indicate RXD TXD CD and DTR activity MPI Inputs Six MPI inputs directly interface the microprocessor on th...

Page 6: ...ut remains at a high 5 VDC logic state Line Select Inputs The line select inputs control the line switching relay When the line select input for line 1 is grounded with input 2 open or at a high logic...

Page 7: ...DTE for commu nication with a remote DTE s modem 460 ACS Master and Remote Modes Refer to Fig 2 One 46020 Multiple Alarm Processor MAP is equipped with 46800 58 firmware and is communicating through a...

Page 8: ...tem refer to the 46800 58 MAP Firm ware Manual HayesTM Mode Refer to Fig 3 When the option switches and straps are set appropriately the 44210 may be used as a HayesTM type compat ible modem for trans...

Page 9: ...eration Refer to Installation section Subassembly The 44210 accepts a plug in subassembly the 49210 Two Line Interface Subassembly It provides an additional backup line so system data may still be tra...

Page 10: ...ront panel plug of the 44210 is removable to allow the subassembly front panel to appear in the front panel cutout The optional 49210 subassembly replaces a subassembly bypass card that is plugged int...

Page 11: ...r operation by the computer or DTE that is interfaced to the 44210 modem The front panel LEDs of the 49210 should be monitored as well Refer to Table C for front panel LED operat ing information TABLE...

Page 12: ...ide 300 Baud on DTE side 1 Stop Bit 2 Stop Bits 8 bit Word Length 7 bit Word Length Even Parity Odd Parity Reserved No Parity Auto Answer Mode 460 Remote Mode 460 ACS REMOTE MODE AUTO ANSWER MODE OR H...

Page 13: ...SEMBLY 1 5 P6 P4 1 5 1 5 ON EXT DTR ON EXT RTS GND TERM 422DTR 422TXD 485TXD 1 OFF 2 S1 S1 S1 1 2 3 4 OFF ON 5 6 7 8 BOTTOM VIEW OF MODULE 8 1 OFF S1 1 2 3 4 OFF ON 5 6 7 8 SWITCH S1 1 THROUGH S1 8 PO...

Page 14: ...TCH SETTINGS 460 ACS AUTO ANSWER MODE INSTALLATION S1 1 2 3 4 OFF ON 5 6 7 8 SWITCH S1 1 THROUGH S1 8 POSITIONS AS SHOWN BOTTOM VIEW OF MODULE S1 1 2 3 4 OFF ON 5 6 7 8 SWITCH S1 1 THROUGH S1 8 POSITI...

Page 15: ...NENT SIDE OF PC BOARD MPI MPI MPI Audio Monitor MPI MPI Line Select 1 Line Select 2 2 Wire Line 1 2 Wire Line 1 Off Hook Ring Detect 1 Ring Detect 2 21 to 56 VDC DTR TTL RTS TTL RXD TTL TXD TTL MPO TT...

Page 16: ...mmand is not followed by a carriage return Dial Precedes the phone number that is to be dialed The last digit of the phone number is followed by a carriage return Pulse Causes a pulse to be sent Touch...

Page 17: ...esult code CONNECT 1200 enabled Enables dial tone detection Enables busy signal detection Enables both dial tone and busy signal detection Long space disconnect disabled Long space disconnect enabled...

Page 18: ...s register Option register Flag register Test modes DEFAULT 0 0 43 13 CR 10 LF 8 BS 2 30 2 6 7 70 50 none none none 0 The 44210 has front panel LEDs that indicate TD Transmit Data DTR Data Terminal Re...

Page 19: ...a DTR handshaking signal from the DTE side Flashes when the module is receiving tones from a data source on the line side Comes ON when carrier tones are detected from a data source on the line side C...

Page 20: ...ufacturer s authorized agent 5 When the installation of this device requires connection or changes to the internal wiring of registered telephones or other registered devices such changes and connecti...

Page 21: ...2 MPO OUTPUTS RS 232 pin 16 TTL CMOS pin 27 WEIGHT 44210 only 44210 w 49210 Subassembly PHYSICAL MEASUREMENTS With or without 49210 Subassembly Operating Temperature Range VALUE 21 to 56 VDC 152mA max...

Page 22: ...tten instrument signed by a duly authorized officer of the Seller and accepted by the Buyer Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the resp...

Reviews: