Maintenance and care
: Preventative maintenance
Maintenance and care
Preventative maintenance
The dehumidifier requires very little attention for trouble free running. All the necessary
safety and control functions have been built in. The fan motor(s) and the compressor have
permanent lubrication and require no particular maintenance.
Injury - risk of cuts and minor skin burns, when you access the inside of the CDP
Be cautious of sharp edges when opening the unit. Internal parts can be very hot or cold.
•
Switch off CDP for half an hour prior to opening it. Avoid touching very hot and cold
parts as e.g. the pipes or evaporator.
•
Avoid touching sharp edges or wear gloves.
The air inlet filter is to be cleaned once a month. The filter is placed in a stand behind the grill
of the air inlet duct. Drip tray and outlet should also be cleaned, so water can run off freely.
Please follow this procedure to perform the monthly service:
Step Action
1
Unlock the two locks underneath the dehumidifier
2
Dismount the front cap by lifting it up and take out the filter.
The filter is located on the rear of the front cap
3
Wash the filter in tepid soapy water or vacuum clean thoroughly.
If the filter is faulty, replace it.
4
Insert filter in the filter holder, reattach the cap and lock the two locks. (From Step 1)
NB:
If the filter (one size PPI filter with order no. 094686) has to be replaced, you can order it
through a Dantherm dealer.
The dehumidifier should be inspected once a year.
Please follow this procedure to perform the annual service:
Step Action
1
Remove the front from the dehumidifier
2
Inspect the inside of the dehumidifier
3
Vacuum clean the dehumidifier to remove any dust or debris
Important: Vacuum clean the condenser thoroughly
4
If necessary wash the lamella evaporator in tepid soapy water if it is badly soiled
Introduction
Warning
Caution
CAUTION
Monthly service