18
Installation
: Electrical connection
Electrical connection
Risk of damaging the dehumidifier, if it has been lying down .
The compressor can be damaged permanently, when the unit is started up just after it has
been lying down.
•
Wait 1 hour with the start up of the dehumidifier, if the unit has been lying down (e.g.
during transport or installation).
Risk of electric shock
An electric shock can cause severe burning and in most extreme cases shock to the brain,
strain to the heart, injury to other organs or result in death.
•
Switch off the power on the main switch, while you open the dehumidifier.
•
Remember also to switch off the power, while you close the dehumidifier.
Step
Description
Illustration
1
Loosen the two screws that
secure the lid to the mains
electricity connection. Tilt the
lid in order to get access to the
terminals.
2
Guide the cable for the power
supply through the PG cable
restrainer.
3
Connect the power to the unit in
accordance with the description
stated on the name plate.
4
Close the lid and fix it with screws again.
Warning
Caution
CAUTION
Warning
Caution
DANGER
Connection of
power supply
2,5 mm2
Min Ø9
Max Ø18