background image

Technical data, continued

These illustrations shows the units dimensions in inch.

78.7

0

20

.7

5

42

.2

2

41

.5

7

14

.5

7

19

.6

9

12

.74

9.71

34.9

7

2.

24

23.6

7

4.4

1

3.

94

3.

53

13

.5

9

34.1

8

41

.8

7

31

.5

1

3.94

4.04

2.0

6

3.

54

Fig. 17 

Dimensions in Inch .

088013 • 

Version 1.0 • 30.01.2015 

en

29

Summary of Contents for Combo Cooling 6000/900

Page 1: ...Combo Cooling 6000 900 Service manual Rev 1 0 en...

Page 2: ...n accept no responsibility for possible errors and changes Irrt mer und nderungen vorbehalten Dantherm n assume aucune responsabilit pour erreurs et modifications ventuelles Dantherm no asume ninguna...

Page 3: ...ion from Dantherm A S Dantherm reserves the right to make changes and improvements to the product and the service manual at any time without prior notice or obligation This service manual covers the f...

Page 4: ...stallation method and installation orientation Not following these instructions could result in injury death or damage to equip ment All work should be performed by qualified personal using safe work...

Page 5: ...s removes dissipated heat from electronic equipment and it s designed to maintain correct temperature for electronic equipment Dantherm recommends that the cooling system should be running continuousl...

Page 6: ...view 1 2 5 4 3 Fig 1 This table refers to the outdoor view above Pos Description 1 Free cooling air inlet 2 Condenser cooling air output 3 Front door with lock 4 Removable side cover for service acces...

Page 7: ...Fig 2 This table refers to the outdoor view above Pos Description 1 Free cooling supply air inlet 2 Return air 3 Cable routing option 1 4 Cable routing option 2 5 Removable installation bracket 6 Cond...

Page 8: ...s table refers to the parts view above Pos Descriptions 1 Free cooling fan 2 Wall bracket frame 3 Embedded controller type CC4 4 Free cooling filter 5 AC free cooling operation shift damper 6 Cable ro...

Page 9: ...led closed loop without cooling Air paths Free cooling Active cooling Circulation Fig 4 Warm internal air is drawn into the unit by the internal evaporator fan at the evaporator opening through the ev...

Page 10: ...s designed to maintain cor rect and steady temperature for the electronic radio equipment The ComboCooler has both free cooling as well as AC cooling thus still having connection for additional exter...

Page 11: ...numbers are product specific See more in unit manual Follow the display leaflet for guidance for usage of the display The controller has an integrated SD card reader that can exchange parameters for i...

Page 12: ...devices NEVER lift the unit by hands use only forklift or similar hoisting device Unpack and prepare unit for mounting Step Action Illustration 1 Remove both side panels 1 Lift side 2 Pull outwards 3...

Page 13: ...0 mm Fig 6 Please make sure that one of the two shown cable run options is achievable Standard option needs drilling holes in wall in center to the units holes Alternative option route the cable in fr...

Page 14: ...r drilling the correct amount of cable inlets min 925 mm optimum 1125 mm or more 500 mm 323 mm 275 mm min 90 mm 800 mm 800 mm 364 mm 25 mm 30 mm 30 mm Drill only cable inlet if needed Fig 8 Fasten the...

Page 15: ...a forklift or similar lifting device 4x DIN 10 Fig 10 Mount the four bolts securing the unit to the frame and seal the edges between unit and wall according illustration 4x DIN 10 Fig 11 Mounting uni...

Page 16: ...e wants to be controlled Please make sure the sensor isn t blocked or touching any metal and isn t placed in the air stream coming from the ComboCooler Fig 12 Please pull cables from inside through wa...

Page 17: ...included t Standard shielded ethernet cable 568A termination both ends Accessory 10A Mini blade terminal FX Littlefuse type 997 010 10A Mini blade terminal FX Littlefuse type 997 010 10A Mini blade t...

Page 18: ...force a specific operation for instance shutting down the cooling system and close the damper in case of a fire J5 alarm 1 2 outputs Dry contact rated 0 5A 60Vdc Normally Open or Normally closed jump...

Page 19: ...Room Sens RS 0 1 1 0 8 Amb Sens AS 0 1 1 0 9 Supp Sens SS 0 1 0 0 10 Cond Sens CS 0 1 0 0 11 Digi 1 I P FIL 0 1 0 0 12 Digi 2 I P FI 0 1 0 0 13 Door Xtch I P DI 0 1 0 0 14 Filt Grd I P FI 0 1 0 1 15...

Page 20: ...n off Force external AC on off In all configuration menu sections the digital input functionality is controllable Cooling Fan Configuration Fan 1 Fan 2 Fan 3 18 Override Digi 1 x 0 100 0 x x 19 Overri...

Page 21: ...nc jumper Be displayed on any connected RS 485 display Be logged on the SD card if available in the SD card reader when alarm is present This table shows the error according the shown E code Code Err...

Page 22: ...it is located in bad quality air environment A written log at site is adequate documentation for preventive maintenance Switch off AC and DC supply before working on the unit Make sure that all work h...

Page 23: ...Fig 15 The unit must be cleaned according to the recommended preventive maintenance plan Tools required Vacuum cleaner or compressed air Soft brush TX20 screwdriver AC cleaning agent if it s very dir...

Page 24: ...s of leakage 3 Are the coil lamellas clean and undamaged 4 Are all fan blades free of any obstructions cracks or missing blades 5 When rotating the fans with the fingers do the fans rotate freely with...

Page 25: ...ue N 2 Damper Supply 3 Damper Supply 1 Damper GND A2 A1 N L Gnd PWM Tacho Postive Gnd PWM Tacho Postive Comp control Comp control Filter Ambient temp Sensor Condensor fan Sensor HP LP Heater Heater He...

Page 26: ...2 3 Pos Description Order no 1 Evaporator fan 012848 2 CC4 controller 075255 3 Damper motor 48V DC 075254 4 Condenser fan 230V AC EC type 075250 5 Compressor 1 phase 230V AC 50Hz 220470 na RS 485 exte...

Page 27: ...55 Refrigerant amount Kg R410a 2 3 Expected service life 10 years Cooling capacity operational data 230V 50Hz Cooling capacity at 27 C internal and 35 C ambient sensible W 7115 Free cooling capacity 4...

Page 28: ...cation Voltage 230V 50Hz 48V DC Circuit Breaker 16A 16A Wire Size 2 5mm2 12AWG 2 5mm2 12AWG These illustrations shows the units dimensions in millimetres 1997 527 1072 1055 370 500 323 246 888 57 601...

Page 29: ...llustrations shows the units dimensions in inch 78 70 20 75 42 22 41 57 14 57 19 69 12 74 9 71 34 97 2 24 23 67 4 41 3 94 3 53 13 59 34 18 41 87 31 51 3 94 4 04 2 06 3 54 Fig 17 Dimensions in Inch 088...

Page 30: ...he following standards EN ISO 12100 1 Machine safety EN 60 950 1 Electrical machinery safety EN 60 335 1 Low voltage EN 60 335 2 40 Low voltage particular requirements for electrical heat pumps air co...

Page 31: ...N tter y 3101 T nsberg Phone 47 33 35 16 00 Fax 47 33 38 51 91 dantherm no dantherm com www dantherm com NO 918 348 328 MVA USA Dantherm Air Handling Inc 110 Corporate Drive Suite K Spartanburg SC 293...

Page 32: ...Dantherm Air Handling A S Marienlystvej 65 7800 Skive Denmark www dantherm com service dantherm com 088013 088013...