background image

R

www.danvex.fi

9

START-UP AND OPERATION 

Description

The control panel is designed to exercise the control functions over the dehumidifier 
operation, change of parameters of operation and maintenance of the specified values 
for these parameters. The panel consists of control buttons and LCD screen.
Buttons  are  used  for  switching  on/off  and  changing  of  parameters  and  modes  of 
operation  of  the  dehumidifier.  At  the  top  of  the  panel  screen  the  current  time  (if 
configured), and operation mode on the basis of the built-in humidity sensor, constant 
operation,  ventilation  mode,  current  values  of  humidity  and  temperature,  set/preset 
humidity value, the status of the timers and their settings are displayed.

Designation

 

of

 

control

 

buttons

:

(ON/OFF) - on / off of the dehumidifier,
(UP) - increase of the parameter (humidity, time),
(DOWN) - decrease of the parameter (humidity, time),
(MODE)  -  Change  (selection)  of  the  operation  mode  (built-in  humidity 
sensor / external humidity sensor / constant dehumidification / ventilation 
mode),
(TIME) - setting the timers and time
(TIMERSET)  -  selection  of  timer  operation  mode  (off  /once  /daily)! 
Names an values of parameter:
INTERNAL - activated internal / built-in humidity sensor, EXTERNAL - 
activated  external  humidity  sensor  (have  to  be  connected,  in  the 
absence of contact, error E7 is displayed),
CURRENT HUMIDITY - current/valid humidity, 
CURRENT TEMPERATURE - current/actual air temperature, 
TIMER ON – time of switching on the dryer when the timer is 
operating;
TIMER OFF – time of switching off the dryer when the timer is 
operating;
OFF - timers are disabled,
TIME - single cycle of the timer operation;

  

EVERY DAY - daily mode of the timer operation.

Control panel of the dehumidifier

Summary of Contents for DEH-1000wp

Page 1: ...DEH 600wp DEH 1000wp Instruction manual Dehumidifiers for swimming pools...

Page 2: ...R www danvex fi 1 Please read this instruction manual carefully and save it before using the dehumidifier If you have any questions about using the dehumidifier please contact Your dealer...

Page 3: ...TION OF THE DEHUMIDIFIER WIRING DIAGRAMS INSTALLATION NOTE START UP AND OPERATION DESCRIPTION OF THE CONTROL PANEL REMOTE CONTROL AND ERROR CODES DEHUMIDIFIER MAINTENANCE TECHNICAL SPECIFICATIONS WARR...

Page 4: ...INTRODUCTION MODELS DEH 600wp DEH 1000wp All the dehumidifiers described in this manual are designed to maintain the relative humidity of indoor air in the range from 40 to 99 at air temperature from...

Page 5: ...insert fingers or any objects into the air intake outlet Do not attempt self repair or re installation of the device If this is done incorrectly it may cause fire electric shock water leakage etc Cont...

Page 6: ...ensure its isolation from moisture If you do not provide isolation of the device from moisture it may cause electric shock If You do not the device may accumulate dirt andcauseafire If You are not go...

Page 7: ...R www danvex fi 6 AIR DEHUMIDIFIERS DEH 600wp and DEH 1000wp DEHUMIDIFIER DESCRIPTION Power cord Power cord Drain hose Moist air input Mounting bracket Dry air output Control panel...

Page 8: ...E 1PH 50 Hz WIRING DIAGRAM PCB PCB Main controller PCB Humidity detector Air temperature sensor System defrost sensor PCB display representation Compressor Fan motor Power source Transformer Protectio...

Page 9: ...e dehumidifier Turn on the dehumidifier for trial use Check the device for presence of abnormal vibration and noise Step 6 Installation is finished and the dehumidifier is ready for use Installation d...

Page 10: ...ons ON OFF on off of the dehumidifier UP increase of the parameter humidity time DOWN decrease of the parameter humidity time MODE Change selection of the operation mode built in humidity sensor exter...

Page 11: ...isabled at excess of the fixed value by 2 3 The clock and timers setting To set the time press the TIME button at the top of the screen the two characters will flash responsible for the clock Then by...

Page 12: ...presented at the LCD display E2 heat exchanger temperature sensor error E3 air temperature sensor error E7 humidity sensor error The scope of supply includes the infrared remote control The remote but...

Page 13: ...the dehumidifier then remove plug from outlet Make sure the air intake and outlet are not blocked Make sure the ground wire is connected properly CAUTION Switch off the dehumidifier or remove the plu...

Page 14: ...TE 1 The nominal value of the noise level recorded in the laboratory 2 In case of difference between the characteristics shown in the table above and the characteristics specified directly on the manu...

Page 15: ...alled in accordance with the manual 2 Equipment which is not operated in accordance with the manual for example in aggressive environments oils salts chlorine etc high temperature multiple cover damag...

Page 16: ...amount of 50 Euro in addition to the transportation costs THIS CONTRACT WARRANTY EXCLUDES ALL OTHER WARRANTIES OR REPRESENTATIONS EXPLICIT OR IMPLIED IN BY ANY DOCUMENTS DATA OR PERSONS THE MAXIMUM LI...

Page 17: ...OF EACH OF ACCESSORIES SEPARATELY BUT IS NOT RESPONSIBLE FOR THE QUALITY OF THEIR JOINT FUNCTIONING EXCEPT WHEN PURCHASED IN THE SET AND INSTALLED ACCORDING TO THE RECOMMENDATIONS OF THE DISTRIBUTOR...

Page 18: ......

Reviews: