background image

R

www.danvex.fi

4

 Read this manual carefully for safety before 

you start operating the dehumidifier. 

Below are 

the symbols used in this manual

.

If dirt sticks to the plug of the power cord 

or plug and socket connection is loose, it 
may cause fire or electric shock.

PRECAUTIONARY MEASURES

CAUTION

 

Remove any dirt from the plug
of the power cord.

There should be no breaks in the cord
or its artificial extensions.

 

Do not scratch or bend the power cord.

Do  not  place  heavy  objects  on  the  power 

cord, heat it, or expose to other factors. The 
cable may be damaged, which can lead to fire 
or electric shock.

Consult Your dealer on installation
of the device.

Do not insert fingers or any objects
into the air intake/ outlet.

Do not attempt self-repair or re-installation
of the device.

If this is done incorrectly, it may cause fire, 

electric shock, water leakage, etc.

Contact Your dealer.

Strictly forbidden

Be sure to follow the

instructions

Provide grounding

Unplug the power cord from

network

Never store anything on the

device

Electric shock hazard

Never insert fingers

or any items

 

 

 

 

 

 

 

Do not disconnect / do not connect
power supply during operation

If during operation there is something
unusual (burning smell, etc.), turn
off the

 

device and disconnect it from

the network

Use grounding.

In case of incorrect operation of the device, 

contact Your dealer.

Avoid contact of the grounding 

wire with gas and water pipes, 
lightning rod or telephone cable. If 
the grounding is made incorrectly, 
it can lead to defeat electric shock

 

hazard.

 

Summary of Contents for DEH-1000wp

Page 1: ...DEH 600wp DEH 1000wp Instruction manual Dehumidifiers for swimming pools...

Page 2: ...R www danvex fi 1 Please read this instruction manual carefully and save it before using the dehumidifier If you have any questions about using the dehumidifier please contact Your dealer...

Page 3: ...TION OF THE DEHUMIDIFIER WIRING DIAGRAMS INSTALLATION NOTE START UP AND OPERATION DESCRIPTION OF THE CONTROL PANEL REMOTE CONTROL AND ERROR CODES DEHUMIDIFIER MAINTENANCE TECHNICAL SPECIFICATIONS WARR...

Page 4: ...INTRODUCTION MODELS DEH 600wp DEH 1000wp All the dehumidifiers described in this manual are designed to maintain the relative humidity of indoor air in the range from 40 to 99 at air temperature from...

Page 5: ...insert fingers or any objects into the air intake outlet Do not attempt self repair or re installation of the device If this is done incorrectly it may cause fire electric shock water leakage etc Cont...

Page 6: ...ensure its isolation from moisture If you do not provide isolation of the device from moisture it may cause electric shock If You do not the device may accumulate dirt andcauseafire If You are not go...

Page 7: ...R www danvex fi 6 AIR DEHUMIDIFIERS DEH 600wp and DEH 1000wp DEHUMIDIFIER DESCRIPTION Power cord Power cord Drain hose Moist air input Mounting bracket Dry air output Control panel...

Page 8: ...E 1PH 50 Hz WIRING DIAGRAM PCB PCB Main controller PCB Humidity detector Air temperature sensor System defrost sensor PCB display representation Compressor Fan motor Power source Transformer Protectio...

Page 9: ...e dehumidifier Turn on the dehumidifier for trial use Check the device for presence of abnormal vibration and noise Step 6 Installation is finished and the dehumidifier is ready for use Installation d...

Page 10: ...ons ON OFF on off of the dehumidifier UP increase of the parameter humidity time DOWN decrease of the parameter humidity time MODE Change selection of the operation mode built in humidity sensor exter...

Page 11: ...isabled at excess of the fixed value by 2 3 The clock and timers setting To set the time press the TIME button at the top of the screen the two characters will flash responsible for the clock Then by...

Page 12: ...presented at the LCD display E2 heat exchanger temperature sensor error E3 air temperature sensor error E7 humidity sensor error The scope of supply includes the infrared remote control The remote but...

Page 13: ...the dehumidifier then remove plug from outlet Make sure the air intake and outlet are not blocked Make sure the ground wire is connected properly CAUTION Switch off the dehumidifier or remove the plu...

Page 14: ...TE 1 The nominal value of the noise level recorded in the laboratory 2 In case of difference between the characteristics shown in the table above and the characteristics specified directly on the manu...

Page 15: ...alled in accordance with the manual 2 Equipment which is not operated in accordance with the manual for example in aggressive environments oils salts chlorine etc high temperature multiple cover damag...

Page 16: ...amount of 50 Euro in addition to the transportation costs THIS CONTRACT WARRANTY EXCLUDES ALL OTHER WARRANTIES OR REPRESENTATIONS EXPLICIT OR IMPLIED IN BY ANY DOCUMENTS DATA OR PERSONS THE MAXIMUM LI...

Page 17: ...OF EACH OF ACCESSORIES SEPARATELY BUT IS NOT RESPONSIBLE FOR THE QUALITY OF THEIR JOINT FUNCTIONING EXCEPT WHEN PURCHASED IN THE SET AND INSTALLED ACCORDING TO THE RECOMMENDATIONS OF THE DISTRIBUTOR...

Page 18: ......

Reviews: