R
www.danvex.fi
1
3
Notices:
1. If the set humidity is higher than the actual humidity, the dehumidifier stops working;
2.
During dehumidification, after the compressor starts working, the fan and compressor
can only be stopped after working for at least 3 minutes; the compressor can only be
re-started 3 minutes after stops;
3.
If works under low temperature, the dehumidifier may judge the system
temperature automatically and defrosts automatically; when defrosting, the indicator of
defrosting is light, the fan works and compressor stops working.
4. The system has auto memory. When all the mode setting has been finished, if there is
sudden power cut during operation, or the power jack slips out, the system may store
the current status before the power is cut and enter the operation mode before power
cut automatically after power is supplied;
5. Range for humidity is 20% -90%;
6. If the dehumidifier is going to be spared for a long time, please unload the power cord
or cut the power.
7. Auto detection of temperature /humidity failure.
a. When the system detects that temperature sensor exceeds the limited range, the system
enters mode of temperature sensor failure. Under this mode, LCD displays temperature
failure code“E1”,the system works in circle of dehumidification for 30 minutes and
defrosting for 15 minutes;
b. When the system detects that humidity sensor exceeds the limited range, the system
enters mode of humidity sensor failure. Under this mode, LCD displays humidity failure
code“E2”and the system enters continuous dehumidification.
c. After temperature /humidity sensor failure is limited, the system works normally.