R
www.danvex.fi
6
For water this is 2250kJ/kg (4.18kJ = 1kcal)
This shows that a relatively large amount of energy is released in the process of water vapor
condensation.
If the moisture to be condensed is not generated at evaporation in the room but is introduced
from outside, e.g. via ventilation, the heat of condensation released in the process will be
used for the room heating.
If it is required to dry materials or rooms the heat energy circulates, i.e. it is consumed during
evaporation and is released during condensation. A large amount of heat energy is generated
at the supplied air dehumidification process, which results in a rise of temperature.
The time necessary for drying of building structures does not depend on the dehumidifying
unit capacity, but is determined by the rate at which the material or the building elements
release the moisture they contain.
Safety Instructions
Prior to delivery the units are subject to comprehensive testing of their materials, functional
capabilities and quality.
However hazards can arise if the unit is operated by untrained persons unfamiliar with its
operation principles or in case the unit is not used for the intended purpose.
The following safety instructions must be observed:
·
It is prohibited to install or operate the units in the locations subject to explosion
hazard.
·
It is prohibited to install or operate the units in the locations with oil, sulphur, chlorine or
salt containing atmospheres.
·
The units must be installed upright.
·
It is prohibited to use a direct jet of water for the unit washing.
·
It is prohibited to cover the air inlet and outlet holes.
·
The intake side of the unit must be free of dirt and loose objects.
·
It is prohibited to insert objects in the unit.
·
It is prohibited to cover or transport the unit during operation.
·
All electric cables outside the unit must be protected against damage (e.g. from
animals etc.).
·
It is necessary to insure that all cables meet the requirements for capacity, length and
purpose.
·
The unit must only be transported in vertical condition. The condensate containers
must be drained prior to each transportation of the unit.
·
It is prohibited to use the unit for purposes other than intended or not specified in this
operations instructions.
In case the requirements are not observed our company disclaims any liability and out
warranty becomes null and void.
Only authorized personnel is permitted to perform works on cooling and
electrical system!