Important information on electrical connections
Electric wiring of the unit should be done in accordance with DIN VDE 0100, Part 704 for
electric current supply sources equipped with automatic circuit-breakers. If the unit is installed
in humid premises such as saunas or basins it should be equipped with proper automatic
circuit-breakers at the buyer's expense.
Commissioning
Prior to commissioning works or to comply with local requirements it is necessary to check air
intake openings and outlet openings to be sure that they are free from foreign matters. Intake
filters condition should be checked as well.
The following instructions are to be observed:
1. Extension cables should be of proper cross-section.
2. It is allowed to use extension cables if they are fully disentangled or stretched!
3. It is not allowed to pull the unit by the power cord.
4. Upon actuation the unit operates in fully-automatic mode.
5. The unit is equipped with a protection device that prevents the compressor from
switching on at restart immediately after the unit switching off, thus preventing the
compressor damage. The compressor switches on after 3 minutes only.
We do not ensure the efficient operation of the unit if the room temperature is below 6°C and
if the relative humidity is below 40 %.