01 . 60

6. The coffee maker will be stand-by for operation as soon as the stand-

by light comes on to signify that the water tank is up to temperature.

7. The coffee maker will be stand-by for operation as soon as the stand-

by light comes on to signify that the water tank is up to temperature.

8. Brew one batch (water only) to confirm proper fill levels.

Quantity of brewing can control increase-decrease by Timer.

9. Re-attach the covers after one final inspection for leaks.

Look closely in the top of the brewer at the dispense fitting during
this inspection.

Troubleshooting

< BREWING PROBLEM >

DIVISION

POSSIBLE CAUSE

SOLUTION

Shot brew levels (Every Brew)
One or half batch are affected 
and levels are consistent.

Spray-cap clogged.

- Clean and replace the spray-cap.

Timers are set too low.

- Advance timers to proper level.

Water filter clogged.

- Change water filter.

Incoming Voltage is too low for timers
to function at proper time sequences.

- Call an electrician in the building.

Shot brew levels (Some Brews)
One or half batch are affected 
and levels are erratic.

Water pressure or flow rate is too low
or fluctuates too much to support a full
brew. (Problem is worse in simultaneous 
brews.)

- Make sure Maker has a dedicated water line.
- Increase the diameter of the water line to the Maker

or stable source.

Water filter clogged. (Problem is worse
during simultaneous brews.)

- Change water filter.

High brew levels (Every Brew)
Overfills but does stop

Timer(s) are set too high.

- Adjust timers down to appropriate level.

High brew levels (Some Brews)

Glass Decanter not empty.

- Empty the Glass Decanter and try again.

Maker basket or filter overflows

Water pressure increase.

- Adjust – Timer.
- Pressure more than 5 Bar: Install Regulator.

Maker won't stop brewing

Bad or stuck fill Solenoid Valve.

- Replace or rebuild the fill Solenoid valve.

Do not install Water-filter.

- Install the water-filter system and replace or rebuild the 

fill solenoid valve. 

< TEMPERATURE PROBLEM >

DIVISION

POSSIBLE CAUSE

SOLUTION

Brew water is cold /
not hot enough,
Stand-by light is OFF.

No power to brewer

- Make sure power switch is on.
- Check power connection. (plug or wire)
- Check building circuit breaker

Bad heater element

- Check amperage draw on heater wires.

Brew water is cold / 
not hot enough,
Stand-by light is ON.

Bad Thermostat (the thermostat
Belive that it is at set temperature)

- Change the new Thermostat

Low brew temperature setting on EGO. - Adjust thermost at (Set it to 'BEST' sign) 

Slower to recover temperature.

One heater fail or water tank limed up

- Check amperage and inspect for lime.

Glass Decanter (Not hot )

Bad heater element

- Change the new warmer heater

Boiling

Thermostat set too high for altitude

- Reduce temperature setting to 5℃ below

Defective thermostat (EGO)

- Replace the thermostat

Summary of Contents for Cofman DW-101 AG

Page 1: ...ully before using the coffee equipment for the first time The coffee equipment which you have just bought is manufactured to strict quality control standards and has been designed applying ergonomical principles so that you will have no problems whatsoever using it and so that it will provide comfortable and safe operation In this manual you will find all the information necessary for installing u...

Page 2: ......

Page 3: ...r hour International electrical configurations available Responsibility temperature for decanters 80 5 for every time REV NAME CODE DOCUMENT 설치시운전 INSTALLATION 추출방법 OPERATING INSTRUCTIONS 유리디켄터 DECANTER 워머히터 교체방법 REPLACEMENT WARMER HEATER 01 60 02 00 02 10 02 50 PARTS DRAWING DIMENSIONS TECHNICAL DATA PART ASSEMBLY BODY HEATING TANK WATER FILLING ELECTRIC WIRING 03 00 05 00 06 00 07 00 08 00 12 00...

Page 4: ... water supply line and inspect both inside and outside of the coffee maker for leaks in all fittings and tubes 2 Turn off the Security Thermostat EGO 3 Turn on the coffee maker s main power switch 4 As SOLENOID VALVE opens water is filled to water tank The heaters will be disabled by the Security Thermostat EGO until the tank is full 5 As shown in the figure please dial according to the specified ...

Page 5: ...crease the diameter of the water line to the Maker or stable source Water filter clogged Problem is worse during simultaneous brews Change water filter High brew levels Every Brew Overfills but does stop Timer s are set too high Adjust timers down to appropriate level High brew levels Some Brews Glass Decanter not empty Empty the Glass Decanter and try again Maker basket or filter overflows Water ...

Page 6: ...d the glass decanter is Press the Brew switch If you want can change a coffee quantity You use timer in coffee maker inside and coffee quantity control is available Before removing the maker basket or glass decanter verify visually that dripping has stopped When the coffee brew finishes please turn on warmer switch CAUTION 1 Before starting the initial brew First about 2 liter at use cold water af...

Page 7: ...ment incorporate higher wattage warmers which can boil liquid If your equipment has warmers over 100 watts you should replace the equipment or post warning to not use glass decanters on the equipment 3 Instruct your employees not to fill refill a customer s cup on the table This increases the chances of serious injury if a decanter breaks because the hot liquid generally spills into the lap of the...

Page 8: ... should be left to qualified personnel in this case 5 Install heater Take care electric leakage so that is not done 6 Rotate porcelain enamel plate to right Clockwise This time if these is any noise between heater and plate Stop turning 7 Connect power supply cord and confirm whether heater operates normally Take care so that water is not inflows to hot plate If water inflows to hot plate breakdow...

Page 9: ... DW 101 AG WATER FILLING AUTO DIMENSIONS WxDxH 228 x 427 x 460 ELECTRICAL CONNECTION 110V 220V POWER CONSUMPTION 2200 W NO OF HOT PLATES 1 BREWING TIME PER POT OF 1 8 LITER 5 Min CAPACITY 15 Cup Cycle 150 Cup Hr MINIMUM BREWING QUANTITY POT STANDARD EQUIPMENT 1 POT 1 BASKET FILTER PAPER 10 inch 108ø x70h ...

Page 10: ...PARTS ASSEMBLY DW 101 AG 05 00 ...

Page 11: ...600L 83610 5 SECURITY THERMOSTAT EGO 16A 110 87200 6 KNOB EGO 84400 7 PCB BOARD 86300 8 PCB BOARD BRACKET 85236 9 TK SUPPORT BRACKET 85231 10 TOP FRAME 85223 11 MIDDLE FRAME 85124 12 PILOT LAMP RED 87203 13 PILOT LAMP GREEN 87202 14 POWER S W 87400 15 BREWING S W 87432 16 BACK COVER 85122 17 SCREW M4 X 10 81301 18 FUSE BREAKER 15A 250V 87600 DW 101 AG BODY ...

Page 12: ...BODY DW 101 AG 06 00 ...

Page 13: ... W 87500 HEATER ELEMENT 110 V 2000 W 87506 11 BOLT M5 X 25 81150 12 ADJUSTMENT BAR 85235 13 O RING I D125 x O D139 8t 84206 14 HOT WATER TANK 2L 82104 15 ADJUSTMENT PLATE 145 X 145 R130 85107 16 INSULATION COVER Φ120 84910 17 CORD GLAND 87901 18 WARMER S W 87420 19 BASE PLATE 84418 20 WARMER FRAME 302 85130 21 RUBBER LEG S 84281 22 SCREW M4 X 20 81302 23 POWER CORD 87700 24 SILICONE TUBE I D7 5 x ...

Page 14: ...HEATING TANK DW 101 AG 07 00 ...

Page 15: ...5 HEAD FILLING BASKET 84406 6 EMBLEM 82141 7 SILICONE TUBE I D7 5 x O D11 5 L220 84222 8 SILICONE TUBE I D7 5 x O D11 5 L110 84222 9 SILICONE TUBE I D14 x O D18 L110 84225 10 SHOWER PLATE 85222 11 SUS PIPE I D6 2 X O D8 X L60 83212 12 SPRAY CAP 82500 13 BOLT M4 X 6 81102 14 BOLT M3 X 6 81346 15 COFFEE BASKET 84401 16 O RING SPRAY CAP 84212 DW 101 AG WATER FILLING ...

Page 16: ...WATER FILLING DW 101 AG 08 00 ...

Page 17: ...W DAJEON 15A 250V 87400 DWL KS WARMER S W DAJEON 6A 250V 87420 DJR KS PILOT LAMP GREEN 87202 DAJEON F 2 KS PILOT LAMP RED 87203 DAJEON F 2 KS FUSE BREAKER 15A 250V 87600 ZE 700S 15 UL POWER CORD 250V 15A 87700 DONG YANG KS MAIN WIRE 2 0mm x 3C 87720 VCTF KS BREWING S W DAJEON 15A 250V 87432 DWL KS PCB BOARD 86300 DWPCB KS TIMER SUNGHO 220V 3MIN 87228 SH MT1 KS RELAY GSR 5A 250V 87225 GPM2L CE SOLE...

Reviews: