background image

 

  

 

 

   

 

Cable Tester Pro 

 

Ordercode: D1909 

 

Return Procedure 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

aftersales@highlite.com

 and request an RMA prior to shipping the 

fixture. Be prepared to provide the model number, serial number and a brief description of the cause for 
the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is 
the customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 
Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 
01)

 

Your name 

02)

 

Your address 

03)

 

Your phone number 

04)

 

A brief description of the symptoms 

 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting. 
 

 

Summary of Contents for Cable Tester Pro

Page 1: ...Cable Tester Pro V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode D1909 MANUAL ENGLISH ...

Page 2: ...rating Determinations 3 Connection with the mains 3 Return Procedure 4 Claims 4 Description of the device 5 Frontside 5 Installation 6 Inserting Replacing the battery 6 Testing a cable 7 Connection Cables 8 Maintenance 9 Replacing the Fuse 9 Product Specifications 10 Dimensions 11 Notes 12 ...

Page 3: ...ox and packing Your shipment includes DAP Audio Cable Tester Pro User manual Safety Instructions Every person involved with the installation operation and maintenance of this system has to be qualified follow the instructions of this manual Before your initial start up please make sure that there is no damage caused by transportation Should there be any consult your dealer and do not use the syste...

Page 4: ...alified engineer inspect for safety before operating If the system has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your system Leave the system switched off until it has reached room temperature If your DAP Audio device fails to work properly discontinue use immediately Pack the unit securely p...

Page 5: ...e number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our announcement that the goods are at their disposal Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of...

Page 6: ...s easy in use and rugged enough for use on the road Must have for every roady 9V Battery operated Speakon 4P Speakon 8P RJ45 RCA XLR 3P XLR 5P 5P Din 6 3 Jack 3 5 Jack Test function for Speakerplug 4 pole Speakerplug 8 pole RJ 45 3 5 Mini Jack 6 3 Jack XLR 5 pole XLR 3 pole RCA 5 pole Din Battery operated Dimensions 187 x 37 x 90mm Frontside Afb 01 ...

Page 7: ...Speakon 4P Socket 25 GND LED 26 Battery Compartment Installation Remove all packing materials from the Cable Tester Pro Check that all foam and plastic padding is removed Connect all cables Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Inserting Replacing the battery Open the battery cover and remove it ...

Page 8: ...low 1 and a Yellow LED will light above each contact on the right side plug connected to 1 on the left side plug Use the tables in appendix 1to verify proper cable connections If no LED lights then there is no connection and the left side contact 1 is floating due to design or an open in the cable Set the rotary switch to 2 to test contact 2 and so on until all contacts have been checked If the Gr...

Page 9: ...ng their life and reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are caused entirely by using unsuitable or faulty cables Unbalanced Balanced For these applications the unit provides 1 4 TRS and XLR connectors to easily interface with most professional audio devices Follow the configuration examples below for your particular connecti...

Page 10: ... cloth Make sure connections are thoroughly dry before linking equipment or supplying electric power Replacing the Fuse Power surges short circuit or inappropriate electrical power supply may cause a fuse to burn out If the fuse burns out the product will not function whatsoever If this happens follow the directions below 01 If the device does not work properly turn the device off 02 Check the bat...

Page 11: ...el Cable Tester Pro Elektrcal Power 1x standard 9V battery Physical Dimensions 190 x 112 x 60 mm LxWxH incl connectors Weight 0 8 kg Design and product specifications are subject to change without prior notice Website www Dap audio info Email service highlite com ...

Page 12: ...11 Cable Tester Pro Ordercode D1909 Dimensions ...

Page 13: ...12 Cable Tester Pro Ordercode D1909 Notes ...

Page 14: ...13 Cable Tester Pro Ordercode D1909 ...

Page 15: ...14 Cable Tester Pro Ordercode D1909 ...

Page 16: ... 2020 DAP Audio ...

Reviews: