Connection with the mains 

 
Connect the device to the mains with the power-plug. 
Always pay attention, that the right color cable is connected to the right place. 
 

International 

EU Cable 

UK Cable 

US Cable 

Pin 

BROWN

 

RED

 

YELLOW/COPPER

 

FASE

 

BLUE 

BLACK 

SILVER 

NUL 

 

YELLOW/GREEN 

GREEN 

GREEN 

EARTH 

 

Make sure that the device is always connected 

properly 

to the earth! 

 
Improper installation can cause serious damage to people and property! 
 

Return Procedure 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

aftersales@highlite.nl

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

1) Your name 
2) Your address 
3) Your phone number 
4) A brief description of the symptoms 
 

Claims 

 
The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting. 
 
 

 

Summary of Contents for CX-1500

Page 1: ...Productcode D4162 D4163 D4164 D4165 D4166 Productname CX 500 CX 900 CX 1500 CX 2100 CX 3000 CX Series Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands MANUAL ENGLISH...

Page 2: ...e mains 4 Return Procedure 4 Claims 4 Functions Features 5 Operation 5 Installation 5 Set Up and Operation 5 Mode Selection 5 Main operation Key Functions 6 Front Panel 6 Rear Panel 6 Speakon output c...

Page 3: ...fer servicing to qualified technicians only IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorized modification...

Page 4: ...kind of cables or defective cables Make sure you use DI boxes to balance unbalanced signals All incoming signals should be clear Never let the power cord come into contact with other cables Handle th...

Page 5: ...er UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your addres...

Page 6: ...pment into a 19 rack Connect all cables Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Set Up and Operatio...

Page 7: ...overheat overload short circuit DC Limit LED Any illumination of the clip LED indicates distortion In this case check the signal of your source and turn down the input gain control Please keep in min...

Page 8: ...h This switch is used to select the operating mode of the power amplifier Stereo 2 inputs channel 1 and 2 and 2 outputs are used Parallel 1 input channel 1 and 2 outputs are used Bridge 1 input channe...

Page 9: ...8 CX Series CX 500 900 1500 2100 3000 Parallel connection Bridge connection...

Page 10: ...ng their life and reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are caused entirely by using unsuitable or faulty cables Unbalanced Ba...

Page 11: ...ohms Construction Protection Protection against short circuits no load on off muting RF interference Ventilation Flow through ventilation from front to back Cooling Internal heat sinks with forced air...

Page 12: ...2013 DAP Audio...

Reviews: