Maintenance 
 

The DAP Audio EM-193B requires almost no maintenance. However, you should keep the unit clean. 
Disconnect the mains power supply, and then wipe the cover with a damp cloth. Do not immerse in 
liquid. Do not use alcohol or solvents. 
Keep connections clean. Disconnect electric power, and then wipe the audio connections with a damp 
cloth. Make sure connections are thoroughly dry before linking equipment or supplying electric power.

 

 

Troubleshooting 

 

DAP Audio EM-193B 

This troubleshooting guide is meant to help solve simple problems. If a problem occurs, carry out the steps 
below in sequence until a solution is found. Once the unit operates properly, do not carry out following 
steps. 

1. 

If the device does not operate properly, set the switch on the EM-193B in OFF position. 

2.

  Check the batteries, etc. 

3.

  If all of the above appears to be O.K., Set the switch in ON position.

 

4.

  If you are unable to determine the cause of the problem, do not open the EM-193B, as this may 

damage the unit and the warranty will become void. 

5. 

Return the EM-193B to your DAP Audio dealer. 

 

 

Product Specification 

 

Type:   

 

 

Dynamic, moving coil 

Polar pattern:   

 

Cardioid 

Frequency Response:   

50-16.000 Hz 

Max. SPL: 

 

 

138 dB (1% THD) 

Power supply:   

 

2x Battery UM3, AA1.5V (not included) 

Carrier Frequency Range: 

502-960 MHz 

RF Output: 

 

 

10 mW 

Stability: 

 

 

±0.005% 

Frequency Deviation:   

±48 kHz 

LCD Display:   

 

Frequency, battery fuel gauge 

Controls: 

 

 

Power On/Off, mode setting, AF Level Control, Frequency Up/Down, Lock- 
on mode 

Spurious Rejection: 

 

<-60 dBC 

Dimensions: 

 

 

Ø 50 mm x L 260 mm 

Net. Weight:   

 

0,262 kg  

 
 
Design and product specifications are subject to change without prior notice.

 

 

 

 

Website: 

www.Dap-audio.info 

   Email: 

service@highlite.nl

 

Summary of Contents for EM-193B

Page 1: ...EM 193B V2 ORDERCODE D145161B ORDERCODE D145182B Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands...

Page 2: ...Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work hard to keep you our cu...

Page 3: ...vice 4 Features 4 Overview 4 Installation 4 Set Up and Operation 5 Placing the batteries 5 Changing the settings 5 Changing the frequency of the transmitter 6 Changing the sensitivity of the microphon...

Page 4: ...lt your dealer and do not use the system To maintain perfect condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes writte...

Page 5: ...ause for the return Be sure to properly pack the device any shipping damage resulting from inadequate packaging is the customer s responsibility Highlite reserves the right to use its own discretion t...

Page 6: ...red by AA batteries True diversity minimum dropouts Overview Fig 1 Installation Remove all packing materials from the EM 193B Check that all foam and plastic padding is removed Always disconnect from...

Page 7: ...have removed the grill You see a small lip which you have to push 3 Pull out the battery holder Put 2 batteries 2x Battery UM3 AA1 5V in the holder Pay attention to the polarity of the batteries and p...

Page 8: ...utton for 3 seconds The display shows FREQUE 2 Tap the set 1 button until the display shows LOC OFF 3 Press the up 3 button to turn the lock function on 4 Press the set 1 button again The display will...

Page 9: ...and telecommunications BIPT www bipt be Czech Republic Czech Telecommunication Office www ctu cz Denmark National Telecom Agency www tst dk Finnland Finnish Communications Regulatory Authority FICORA...

Page 10: ...uct shall be marked with the CE conformity marking and our Notified Body number as shown on the right 1856 Th f i b d d i ifi d b T V Rh i l d N ifi d B d Supplementary Information I hereby declare un...

Page 11: ...uct shall be marked with the CE conformity marking and our Notified Body number as shown on the right 1856 Th f i b d d i ifi d b T V Rh i l d N ifi d B d Supplementary Information I hereby declare un...

Page 12: ...set the switch on the EM 193B in OFF position 2 Check the batteries etc 3 If all of the above appears to be O K Set the switch in ON position 4 If you are unable to determine the cause of the problem...

Page 13: ...2014 DapAudio...

Reviews: