background image

 

WARNING 

 
 
 
 
 
 

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY  

BEFORE YOUR INITIAL START-UP! 

 

SAFETY INSTRUCTIONS 

Every person involved with the installation, operation and maintenance of this system have to: 

-

 

be qualified 

-

 

follow the instructions of this manual 

 
 
 
 

 

 
 
 

Before you initial start-up, please make sure that there is no damage caused by transportation. Should there 
be any, consult your dealer and do not use the system. 
 
To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to follow 
the safety instructions and warning notes written in this manual. 
 
Please consider that damages caused by manual modifications to the system are not subject to warranty. 
 
This system contains no user-serviceable parts. Refer servicing to qualified technicians only. 
 

IMPORTANT:

 

The manufacturer will not accept liability for any resulting damages caused by the non-observance 
of this manual or any unauthorized modification to the system. 

 

 

Never let the power-cord come into contact with other cables! Handle the power-cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Do not insert objects into air vents. 

 

Do not connect this system to a dimmer pack. 

 

Do not switch the system on and off in short intervals, as this would reduce the system’s life. 

 

Do not open the device and do not modify the device. 

 

Do not open this device. Risk: hazardous radiation exposure. 

 

Only use system indoor, avoid contact with water or other liquids. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always disconnect power from the mains, when system is not used. Only handle the power-cord by 
the plug. Never pull out the plug by tugging the power-cord. 

 

Make sure you don’t use the wrong kind of cables or defective cables. 

 

Make sure that the signals into the mixer are balanced, otherwise hum could be created. 

 

Make sure you use DI boxes to balance unbalanced signals; all incoming signals should be clear. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

CAUTION! 

 

Keep this system away from rain and moisture! 

 

CAUTION! Be careful with your operations. 

With a dangerous voltage you can suffer 

a dangerous electric shock when touching the wires!

 

 

Summary of Contents for IPS-EA

Page 1: ...IPS EA ORDERCODE D6504 ...

Page 2: ...ed You can rely on DAP Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied You can get some of the best quality best priced products on the market from DAP Audio So next time turn to DAP Audio for more great audio equipment Always get t...

Page 3: ...S EA Guide Warning Safety instructions Operating Determinations Connecting to the mains Description Features Overview Front panel Overview Back panel Operation Connecting the device Remote in connection Maintenance Troubleshooting Product Specifications ...

Page 4: ...rd and all connections with the mains with particular caution Never remove warning or informative labels from the unit Never use anything to cover the ground contact Do not insert objects into air vents Do not connect this system to a dimmer pack Do not switch the system on and off in short intervals as this would reduce the system s life Do not open the device and do not modify the device Do not ...

Page 5: ...h when changing the power cord or signal cable or select the input mode switch In typical use please set the volume at 0dB position Sometimes when you want to send one signal to more than one amplifier you should use a signal distributor If your Dap Audio device fails to work properly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to yo...

Page 6: ... your own safety and the safety of others Connection with the mains Connect the device to the mains with the power plug Always pay attention that the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER FASE N BLUE BLACK SILVER NUL YELLOW GREEN GREEN GREEN EARTH Make sure that the device is always connected properly to the earth I...

Page 7: ... 5 RESET SW Manual reset switch Pressing this switch will reset the alarm 6 PLAY Led Lights up in PLAY status 7 PLAY REC Pressing this switch will set the unit in PLAY mode The PLAY led will light The recorded message will be played back Pressing the switch again will stop the recorded message Holding the switch for 5 seconds will set the unit in Record mode Now you can use either the supplied MIC...

Page 8: ...ith a fuse of same specification T315mA 14 GND Screw This screw offers a separate ground connection Can be useful in case of grounding problems 15 DC 24V Input Used to connect an external back up power supply of 24Vdc e g Battery 16 GND Lift Switch To eliminate grounding problems 17 Remote Out A B Relay outputs N O contacts are closed if an alarm signal is present 18 Remote In A B Need to be conne...

Page 9: ...eeds 2U rackspace Connect all cables Connecting the device Below an example of a possible setup NOTE Always turn off and disconnect the amplifier from mains voltage before making any connections Fig 3 NOTE If you re not confident in how to connect either low impedance or High impedance 100V Speakers to your Intelligent Speaker Selector Always ask a qualified technician ...

Page 10: ...out the product will not function whatsoever If this happens follow the directions below to do so 1 Unplug the unit from electric power source 2 Insert a flat head screwdriver into a slot in the fuse cover Gently pry up the fuse cover The fuse will come out 3 Remove the broken fuse If brown or unclear it is burned out 4 Insert the replacement fuse into the holder where the old fuse was Reinsert th...

Page 11: ...e Website www Highlite nl Email service highlite nl Power supply AC 110 120V 220 240V 60Hz 50Hz DC 24V Remote in Short circuit signal Remote out Short circuit signal Output alarm signal 1v 0dB 10kΩ Recording time 120 seconds Recording level 20dBV line in Dimensions WxHxD 483x370x88mm Net weight 6 05kg ...

Page 12: ...2007 DapAudio ...