Only use device indoor, avoid contact with water or other liquids. 

 

Only operate the fixture after having checked that the housing is firmly closed and all screws are 
tightly fastened. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only 
handle the power-cord by the plug. Never pull out the plug by tugging the power-cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power-cord is never crimped or damaged. Check the device and the power-
cord from time to time. 

 

Make sure that there is sufficient room on all sides of the system for air circulation. 

 

Make sure you don’t use the wrong kind of cables or defective cables. 

 

Make sure that signals into the mixer are balanced, otherwise hum could be created. 

 

Avoid ground loops! Always be sure to connect the power amps and the mixing console to the 
same electrical circuit to ensure the same phase! 

 

Please turn off the power switch, when changing the power cord or signal cable. 

 

Make sure that the amplifier is turned down, before turning the power on or off. So you can avoid 
supersonic frequencies, which could damage your speakers. 

 

Make sure that the amplifier is turned down, before turning the power on or off. So you can avoid 
supersonic frequencies, which could damage your speakers. 

 

Don't put your equipment next to TV, radio, etc., because of interference or distortion. 

 

If you connect other parts of the system, be careful of ground loops. 

 

The best way to avoid ground loops is connecting the electrical system ground to one central 
point ("star" system). In this case the mixer can act as a central point. 

 

To prevent humming, please try different combinations of ground-lift or connect all chassis to the 
system ground, either by a power cable or frontcover rack screws. 

 

Before changing the ground, always turn off your amplifier. 

 

Please read this manual carefully and keep it for future reference. Remember that the amplifier 
has a better value on the market, if you save the carton and all packing materials. 

 

Prevent distortion! Make sure that all components connected to the Palladium have sufficient 
power ratings. Otherwise distortion will be generated because the components are operated at 
their limits. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do 
not switch it on immediately. The arising condensation water might damage your device. Leave 
the device switched off until it has reached room temperature. 

 

If your Dap Audio  device fails to work properly, discontinue use immediately. Pack the unit 
securely (preferably in the original packing material), and return it to your Dap Audio  dealer for 
service. 

 

Never attempt to bypass the thermostatic switch or fuses. 

 

Allow time to cool down, before cleaning or servicing.  

 

For replacement use fuses of same type and rating only. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 
 

Operating Determinations 

If this system is operated in any other way, than the one described in this manual, the product may suffer 
damages and the

 

warranty becomes void.  

Any other operation may lead to dangers like short-circuit, burns, electric shock, etc. 
 
You endanger your own safety and the safety of others! 
 

Improper installation can cause serious damage to people and property !

 

 

Summary of Contents for Palladium P-400

Page 1: ...00 ORDERCODE D4132 B P 700 ORDERCODE D4133 B P 900 ORDERCODE D4134 B P 1200 ORDERCODE D4135 B P 1600 ORDERCODE D4136 B P 2000 ORDERCODE D4137 B Highlite International B V Vestastraat 2 6468 EX Kerkrad...

Page 2: ...on DAP Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work hard to keep you...

Page 3: ...allel Operation 9 Bridged Mono Operation 10 Switches and controls 10 Input Attenuators 10 Mode Select Switch 10 Ground Lift Switch 10 Indicators 10 Clip LED 10 Signal LED 11 Protect LED 11 Power LED 1...

Page 4: ...difications to the device are not subject to warranty This device contains no user serviceable parts Refer servicing to qualified technicians only IMPORTANT The manufacturer will not accept liability...

Page 5: ...mixer can act as a central point To prevent humming please try different combinations of ground lift or connect all chassis to the system ground either by a power cable or frontcover rack screws Befor...

Page 6: ...method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of t...

Page 7: ...00 Stereo mode Stereo mode 2x 180 Watt RMS 8 2x 600 Watt RMS 8 2x 270 Watt RMS 4 2x 900 Watt RMS 4 Bridged mode 540 Watt RMS 8 Bridged mode 1800 Watt RMS 8 P700 P2000 Stereo mode Stereo mode 2x 240 Wa...

Page 8: ...7 Backside Fig 2 5 IEC Power connector 6 Fuse 7 5 way Binding post output Connectors 8 Signal Ground Lift Switch 9 Bridged Parallel Stereo 10 Balanced Phone Jack Inputs...

Page 9: ...ept the line level output of most devices The correct input depends on 2 factors 1 whether the input signals are balanced or unbalanced and 2 whether the signal source floats or has ground reference F...

Page 10: ...m the AC mains depends on many factors its load output level or the crest factor of its program material The power requirement is rated under typical music conditions with both channels driven so thos...

Page 11: ...the end of this manual for standard voltage gain and input sensitivity information When operating the amplifier in bridged mode both attenuates must be in the same position so the speaker load will be...

Page 12: ...at sink temperature reaches 90 C which may indicate an obstructed air supply clogged air filter etc the channel will disconnect its load Normal operation will resume automatically once it cools to 80...

Page 13: ...em This gives the advantage of increasing their life and reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are caused entirely by using un...

Page 14: ...screwdriver to the left at the same time gently push a bit Turn and Push The fuse will come out 3 Remove the used fuse If brown or unclear it is burned out 4 Insert the replacement fuse into the holde...

Page 15: ...0K balanced 10K unbalanced 20K balanced 10K unbalanced 20K balanced 10K unbalanced 20K balanced 10K unbalanced 20K balanced 10K unbalanced SNR 105dB 105dB 105dB 105dB 105dB 105dB 105dB Crosstalk 60dB...

Page 16: ...16 2 3 4 5 1 5 0 58 1 16 2 3 2 5 0 35 0 7 1 39 4 0 22 0 44 0 87 5 0 5 4 3 8 2 15 5 0 75 2 9 5 6 10 8 1 5 1 45 2 9 5 6 2 5 0 87 1 74 3 4 4 0 55 1 09 2 2 6 0 37 0 73 1 45 10 0 5 8 24 15 5 28 0 75 5 6 10...

Page 17: ...2 ohm load 5 18 0 81 1 61 3 2 16 0 51 1 02 2 14 0 32 0 64 1 28 12 0 2 0 4 0 8 10 0 128 0 25 0 51 10 18 1 61 3 2 6 2 16 1 02 2 4 14 0 64 1 28 2 5 12 0 4 0 8 1 6 10 0 25 0 51 1 01 40 18 6 2 11 9 22 16...

Page 18: ......