background image

 

Connection with the mains

 

Connect the device to the mains with the power-plug. 
Always pay attention, that the right color cable is connected to the right place. 
 

International  EU (including UK) From April 2004  North America 

Pin 

Brown 

Black 

Phase  

Blue 

White 

Neutral 

 

Green/Yellow 

Green 

Protective Earth 

 

Make sure that the device is always connected 

properly

 to the earth! 

 
 
 
 
 
 
 
 
 
 

      

Return Procedure 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

aftersales@highlite.nl

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

1) Your name 
2) Your address 
3) Your phone number 
4) A brief description of the symptoms 

 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
 It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting.  
 

   
 
 

Summary of Contents for Palladium P-400

Page 1: ...00 ORDERCODE D4132 B P 700 ORDERCODE D4133 B P 900 ORDERCODE D4134 B P 1200 ORDERCODE D4135 B P 1600 ORDERCODE D4136 B P 2000 ORDERCODE D4137 B Highlite International B V Vestastraat 2 6468 EX Kerkrad...

Page 2: ...on DAP Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work hard to keep you...

Page 3: ...allel Operation 9 Bridged Mono Operation 10 Switches and controls 10 Input Attenuators 10 Mode Select Switch 10 Ground Lift Switch 10 Indicators 10 Clip LED 10 Signal LED 11 Protect LED 11 Power LED 1...

Page 4: ...difications to the device are not subject to warranty This device contains no user serviceable parts Refer servicing to qualified technicians only IMPORTANT The manufacturer will not accept liability...

Page 5: ...mixer can act as a central point To prevent humming please try different combinations of ground lift or connect all chassis to the system ground either by a power cable or frontcover rack screws Befor...

Page 6: ...method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of t...

Page 7: ...00 Stereo mode Stereo mode 2x 180 Watt RMS 8 2x 600 Watt RMS 8 2x 270 Watt RMS 4 2x 900 Watt RMS 4 Bridged mode 540 Watt RMS 8 Bridged mode 1800 Watt RMS 8 P700 P2000 Stereo mode Stereo mode 2x 240 Wa...

Page 8: ...7 Backside Fig 2 5 IEC Power connector 6 Fuse 7 5 way Binding post output Connectors 8 Signal Ground Lift Switch 9 Bridged Parallel Stereo 10 Balanced Phone Jack Inputs...

Page 9: ...ept the line level output of most devices The correct input depends on 2 factors 1 whether the input signals are balanced or unbalanced and 2 whether the signal source floats or has ground reference F...

Page 10: ...m the AC mains depends on many factors its load output level or the crest factor of its program material The power requirement is rated under typical music conditions with both channels driven so thos...

Page 11: ...the end of this manual for standard voltage gain and input sensitivity information When operating the amplifier in bridged mode both attenuates must be in the same position so the speaker load will be...

Page 12: ...at sink temperature reaches 90 C which may indicate an obstructed air supply clogged air filter etc the channel will disconnect its load Normal operation will resume automatically once it cools to 80...

Page 13: ...em This gives the advantage of increasing their life and reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are caused entirely by using un...

Page 14: ...screwdriver to the left at the same time gently push a bit Turn and Push The fuse will come out 3 Remove the used fuse If brown or unclear it is burned out 4 Insert the replacement fuse into the holde...

Page 15: ...0K balanced 10K unbalanced 20K balanced 10K unbalanced 20K balanced 10K unbalanced 20K balanced 10K unbalanced 20K balanced 10K unbalanced SNR 105dB 105dB 105dB 105dB 105dB 105dB 105dB Crosstalk 60dB...

Page 16: ...16 2 3 4 5 1 5 0 58 1 16 2 3 2 5 0 35 0 7 1 39 4 0 22 0 44 0 87 5 0 5 4 3 8 2 15 5 0 75 2 9 5 6 10 8 1 5 1 45 2 9 5 6 2 5 0 87 1 74 3 4 4 0 55 1 09 2 2 6 0 37 0 73 1 45 10 0 5 8 24 15 5 28 0 75 5 6 10...

Page 17: ...2 ohm load 5 18 0 81 1 61 3 2 16 0 51 1 02 2 14 0 32 0 64 1 28 12 0 2 0 4 0 8 10 0 128 0 25 0 51 10 18 1 61 3 2 6 2 16 1 02 2 4 14 0 64 1 28 2 5 12 0 4 0 8 1 6 10 0 25 0 51 1 01 40 18 6 2 11 9 22 16...

Page 18: ......