background image

7

Power LED

This indicator LED lights, when the amplifier has been turned on, AC power is available and the low-voltage
power supply and fan are operational

Protection Features

Every amplifier incorporates several circuits to protect themselves and the speakers under virtually any
situation. Dap Audio has attempted to make the amplifier as “foolproof” as possible by making it impervious
to short and open circuits, DC Voltage and overheating.

When a problem occurs, that causes a channel to go into a protection mode, the Power LED will dim.
DC voltage on the output, excessive subsonic frequencies, or thermal overloads will cause the channel’s
output relay to disconnect the speaker load, until the problem is corrected or the amplifier cools down.

The internal fan will keep the amplifier operating well within its intended temperature range under all normal
conditions.

When a channel’s heat sink temperature reaches 90 ºC, which may indicate an obstructed air supply,
clogged air filter, etc, the channel will disconnect its load. Normal operation will resume automatically once it
cools to 80 ºC. During this time, the channel’s Power LED will dim.

Short Circuit

If an output is shorted, the protection circuit will be more sensitive, than in the normal protection situation
and will protect the channel’s output transistors from the current stress. The channel’s Power LED will dim.
If the short circuit remains, the channel will eventually thermally protect itself by disconnecting the load.

DC Voltage Protection

If an amplifier channel detects DC voltage at its output, its output will immediately open to prevent speaker
damage. The channel’s Power LED will dim.

Subsonic Frequencies

All amplifiers have a built-in subsonic frequency protection circuit, cornered at 10Hz, for each channel.
An additional feature is a special high frequency protection technology, which enables you to automatically
disconnect speakers, when excessive high frequency energy appears at the output.

Turn-On/Turn-Off-Protection

At power up, the speakers are disconnected. The power supplies charge for about 2-3 seconds and
stabilize, and then the speakers are connected. When power is removed, speaker loop is synchronized with
the turn off signal, therefore no thumps or pops are heard.

Speaker-Protection

All amplifiers automatically protect speakers from DC voltage, subsonic signals and excessive high
frequency signal, but users should be aware of the application limits of their speakers.
Be aware that the amplifiers power does not exceed the speaker’s power capabilities.

Summary of Contents for VPA-060

Page 1: ...Palladium 100V VPA 060 ORDERCODE D4141 VPA 150 ORDERCODE D4142 VPA 250 ORDERCODE D4143...

Page 2: ...on DAP Audio for more excellent audio products We design and manufacture professional sound equipment for the entertainment industry New products are being launched regularly We work hard to keep you...

Page 3: ...p Audio Palladium 100V Series Product Guide Warning Safety instructions Operating Determinations Description Features Frontside Backside Installation Set Up and Operation Connection Cables Maintenance...

Page 4: ...ver remove warning or informative labels from the unit Do not open the device and do not modify the device Do not insert objects into air vents Do not connect this device to a dimmerpack Do not switch...

Page 5: ...k disconnect mains power supply immediately Have a qualified engineer inspect for safety before operating If the device has been exposed to drastic temperature fluctuation e g after transportation do...

Page 6: ...Aux 1 Control 2 CLIP SIGNAL POWER LEDs 9 Mic 2 Control 3 Z1 Z2 Z3 Z4 Switches LEDs 10 Mic 1 Control 4 M Volume Control 11 Mic 2 Input Jack 5 Treble Control 12 Mic 1 Input Jack 6 Bass Control 13 Chime...

Page 7: ...uct on 240V power or vice versa Do not supply power before all components of the system are set up and connected properly DC power or battery supply s connection The unit will also operate with 2 exte...

Page 8: ...or unbalanced and 2 whether the signal source floats or has ground reference Connecting Power The actual current draw the amplifier demands from the AC mains depends on many factors its load output le...

Page 9: ...s shorted the protection circuit will be more sensitive than in the normal protection situation and will protect the channel s output transistors from the current stress The channel s Power LED will d...

Page 10: ...always to your advantage Periodically check that your cables are in good condition that they are correctly wired and that all their contacts are perfectly efficient a great number of problems faulty c...

Page 11: ...or supplying electric power Troubleshooting DAP Audio Palladium 100V Series This troubleshooting guide is meant to help solve simple problems If a problem occurs carry out the steps below in sequence...

Page 12: ...to Noise Ratio Microphone 1 2 66dB Aux 1 2 70dB Tone Bass 10 dB at 100 Hz Treble 10 dB at 10 Hz Muting function Mic 1 overrides other input signals with 0 30dB attenuation Input Connectors 2 x XLR 2 x...

Page 13: ...2005 DapAudio...