5. Commissioning / Shut-down Procedure
40
OM Hydraulic aggregate, Version 1.0 01/2013
5.1.1
Starting up after a power cut
Note the information provided in the product manual for the hydraulically
driven device.
Please refer to the enclosed manufacturer's documentation for information
on starting up the petrol engine.
The electric motor is started up by switching on the main switch.
The pneumatic motor is started up by activating the vacuum trigger.
5.1.2
Filling the oil tank with hydraulic oil
Only the hydraulic oils listed in the chapter Technical Data may be used.
When topping up hydraulic oil, note that the oil level may increase during operation
if tools are connected.
5.2 Shut-down
Procedure
Secure the device from mistaken or unauthorised start-ups and disconnect it
from the energy supply.
Please also note the information in the relevant manufacturer's documentation
for the drive motors.
The control valve of the hydraulically driven device must be in the zero position in
order to switch off or disconnect the quick-release coupling. First disconnect the
feed and then the return.
Please also note the information provided in the manufacturer's documentation.
If the hydraulic aggregate is shut down for long periods, condensate may form in
the oil tank. To counteract this, we recommend filling the oil level to its maximum
once the device has cooled down.
To secure against other people starting up the
device, all users must use their own individual padlock.