6 Hydraulic Aggregate Operation
OM Hydraulic Aggregate, Version 1.0 01/2013
43
6
Operating the Hydraulic Aggregate
Before work, follow the safety instructions in chapter 2.
6.1
Connecting to the Supply
6.1.1
Fuelling the petrol engine
Please refer to the enclosed manufacturer's documentation for information
on fuelling the petrol engine.
6.1.2
Connecting the electric motor
The rated energy supply value can be found on the motor type plate or in the tech-
nical documents.
Connection to the supply network takes the form of a CEE17 device plug. The
mains for connecting to the energy supply must be a TN-S system. A connection
cable with IEC 60309-2, CEE17 coupling socket, appropriate for the motor used, is
required for the connection.
6.1.3
Connecting the pneumatic motor
There is a claw coupling (claw spacing of 40 mm) on the device.
The rated width of the device connection is 1/2 ". We recommend one rated width
bigger for the supply cable.
Minimum input pressure > 3 bar. If pressure drops below 3 bar, the vacuum trigger
trips.
For more detailed information, please refer to the manufacturer's documenta-
tion for the pneumatic motor.
6.2
Installing the Hydraulic Aggregate
The device must be installed on a level surface. When installing the device, it must
not be tilted by more than 10° in any direction. During operation, the device must
be secured against slipping with suitable equipment.
The stop point for the fastening must be on the frame.
6.3
Transporting the Hydraulic Aggregate
The handle bar must be extended to pull the device. After transport, the handle bar
should be returned to its original position. Never walk backwards when carrying