Basic Troubleshoong 

If the following remedies do not correct a problem, disconnect the amplifier from the  

power and contact your authorized dealer or service centre.

 

Symptom

    

Cause

    

Remedy

    

The unit does not 
power up when the 
Power Switch is 
Pressed

 

1. 

No Power to unit 

2. 

Blown Fuse

 

1.      Check that amplifier is plugged into a powered electrical outlet 

2. 

Check if the power cable is plugged into the power socket  on 
the rear panel of the amplifier 

3. 

Check the fuse

 

The unit powers up. 
Vacuum tube does 
not light up or glow

 

1. 

Tube not seated 

2. 

Tube is defec(ve

 

1.     Check tube 

2.     Replace tube

 

No Sound from 
Speakers connected 
to amplifier

 

Turntable working, 
URANUS seems to be 
working

 

1.      Check selector switch: make sure proper input selected 

2. 

Ensure that phono output is connected to MM input 

3. 

Check that phono output is connected to preamp LINE input

 

Poor sound stage, 
poor audio presence, 
an unnatural sound 
and insufficient low 
range tonal quality

 

Speaker Polari(es are 
reversed and not un-
matched to the polari-
ty of the amplifier

 

1. 

Check speaker connec(ons: Right  speaker output connec(on 
for right speaker. Le3 output  connec(on for le3 speaker

 

2. 

Check that  speaker polarity connec(ons are correct: Red of 
amp  to  speaker (+); Black of  Amp to black of  speaker(-)

 

Sound is distorted

 

Turntable working, 
sound volume is low 
distorted

 

1. 

Check to see if proper cartridge input is selected: MM 

2. 

Check se8ng of URANUS

 

3. 

Change tube

 

Warranty 

See two-year warranty details enclosed with your URANUS Amplifier.

 

Tube

The

    

Purity

    

of

    

Sound

    

WorldWide Sales & Marke(ng Office: Luen Hing Electrical (HK) LTD. 

Address: G/F., 152 Apliu Street, Shamshuipo, Kowloon, Hong Kong 

Tel: +852 2728 8745 

Email: info@dared.com.hk 

www.dared.com.hk 

Specificaons 

Power Output:…………………………………..50Wx2(KT-88)

 

S/N Ra(o (Phono):…………………………………………..78dB

 

Distor(on:……………………………………………..0.1% (10W)

 

Max. Power Consump(on:…………………………….300W

 

S/N Ra(o (LINE):………………………………………………86dB

 

Power Supply:……………………..AC115V/230V 50-60Hz

 

Input Sensi(vity:…………………………………………..300mV

 

Tubes:…………………………….KT88x4, 12AX7x2, 6SN7x2

 

Unbalanced Input Impedance:…………………..80kohms

 

Dimensions:…………………….430x350x180mm(LxWxH)

 

Balanced Input Impedance:……………………….95kohms

 

Weight:……………………………………………………………30kg

 

Frequency Response:……………………20Hz-50kHz (5W)

 

MM Input Sensi(vity:…………………………………….3.5mV

 

Output Impedance:……………………….4ohms or 8ohms

 

MM Impedance:……………………………………….47k/68pF

 

Full Func(on IR Remote Control

 

Power Tube can be replaceable by match pair of KT-

100, KT-120, KT-150

 

URANUS 