3
Models & Options
Specifications
EZ VFD MODELS
*NOTE: Output Freq greater than 60Hz must de-rated load current by up to 20%. See de-rate chart under Max Trimpot setting.
EZ VFD Electrical
EZ VFD
Mechanical
EZ VFD
Environmental
Models
Description
VF-100C
Open chassis, universal AC input, 230VAC 3 Phase Out, Potentiometer / 0-5VDC
follower speed adjustment; MIN, MAX, BOOST, ACCELERATION, DECELERATION,
CURRENT LIMIT, BRAKING trimpot adjustments
VF-100E
NEMA 4X enclosed, universal AC input, 230VAC 3 Phase Out, Potentiometer / 0-
5VDC follower speed adjustment; MIN, MAX, BOOST, ACCELERATION,
DECELERATION, CURRENT LIMIT, BRAKING trimpot adjustments
Options
Description
-MBRTU
Optional field installable ModBusRTU Serial Interface – see details in separate manual
-R
Optional Form C Run Relay output – Factory installed only
-TP
Optional removable Trimpot Board – Factory supplied only
Housing Type ................................................................................................................ Open Chassis or NEMA 4X
Connector Style ................................................................... ¼” male spade terminals for supply voltage and motor
Terminal Block Torque Setting .................................................................... 1.95 in lb (.22Nm) to 2.21 in lb (.25Nm)
Housing Material ........................................................................... 6063-T6 Aluminum / Sabic NORYL TYPE N190
Length ..........................................................................................................................................7.150", 181.61mm
Width ............................................................................................................................................ 5.53", 140.46mm
Height ..........................................................................................................................................5.942", 150.93mm
Weight ....................................................................................................................... 3.177 lb, 50.832 oz, 1441.06g
Operating Temperature Range ....................................................................................... -10C to 40C (14F to 104F)
Operating Humidity Range .................................................................................................... 95%, non-condensing
®
®
®
MODELS
INPUT
VOLTAGE
INPUT
FREQ
INPUT
PHASES
OUTPUT
VAC
OUTPUT
PHASES
OUTPUT
FREQ
OUTPUT
I/PH
VF-100C
115
230
50/60
50/60
1 Ph
1 Ph
230
230
3
3
0 – 60/120*
0 – 60/120*
2.4 Amps
3.2 Amps
VF-100E
115
230
50/60
50/60
1 Ph
1 Ph
230
230
3
3
0 – 60/120*
0 – 60/120*
2.4 Amps
3.2 Amps
Line Input Voltage (Min – Max) ....................................................................................... Any Voltage from 110-240 VAC
Line Input Frequency ........................................................................................................... Any Freq. from 48-70 Hertz
Speed Voltage Signal Input (+5VDC from terminal block) ................................................................................. 0-5 VDC
Motor Inverter Voltage Output ...................................................................~230VAC effective, ~390Vpk PWM @ 8KHz
Boost Slope ........................................................................................................................................................ 3V / Hz
Onboard Power Supply (Externally Accessible) ............................................................................................ 5V @ 25mA
®