background image

11

Manual del Usuario

 / aero 

40A

 / 

User’s Manual

Label details

Zone for

user notes

SIGNAL

INPUT

CAUTION

DO NOT EXPOSE THIS EQUIPMENT

TO RAIN OR MOISTURE

RISK OF ELECTRIC SHOCK

DO NOT OPEN

D.A.S. AUDIO S.A. (

MADE IN SPAIN 

Valencia)

N1918

LOOP
THRU

ON

IDENTIFY
/COMMS

SIGNAL

/LIMIT

AMPLIF.

PROTECT

THROW

HIGH PASS FILTER

TO UNLOCK,

PRESS AND HOLD OK

FOR 2 SECONDS

NUMBER OF UNITS

IN

OUT

IDENTIFY

NUMBER OF UNITS

UNIT NAME

STAGE / VENUE

THROW

HIGH PASS FILTER

115/230 V~ 50/60Hz 620W

AC INPUT

MAX. 6@230V / 3@115V UNITS IN PARALLEL

AC OUTPUT

ID DASNET

02394

ON / OFF
A  sound  system  should  be  switched  on 

sequentially. Switch on the self-powered units last 
in your sound system (switch on the subwoofer 
before the mid-high system). Switch on the sound 
sources such as CD players or turntables, then the 
mixer,  then the  processors, and  finally  the  self-
powered  unit.  If  you  have  several  units,  it  is 
recommended  that  you  switch  them  on 
sequentially one at a time.

Follow the inverse order when switching off, 

turning  self-powered  units  off  before  any  other 
element in the sound system.

Disconnect the device by removing the mains 

connector  from  the  mains  socket.  The  mains 
connector and mains socket must always be freely 
accessible and never covered or blocked in any 
way. 

The models use a power cable equipped with 

a Neutrik PowerCon TRUE1 connector. Power can 
be daisy chained via the TRUE1 output connector 
(see details on product label).

IMPORTANT:  Do  not  disconnect  the  unit 

while in use.

Ensure that the device is disconnected from 

the mains by observing that the ON LED is turned 
off. Please note that the ON LED can stay on for 
several seconds after the mains power has been 
disconnected.

Overheating

This  equipment  does  not  normally  overheat 

during normal conditions of use. When overheating 
occurs, the unit protects itself. You should then 
find  out  why  and  if  necessary  contact  an 
authorised dealer for technical assistance.

Equalisation
The unit does not need extreme settings of 

equalisation to produce quality sound. Avoid high 
levels of gain on the equalisers. Gain values above 
+3 dB on a console’s EQ are not recommended.

Overload indicator

This device has a SIGNAL/LIMIT indicator. The 

red light indicates the signal is excessive.

The  indicator  should  not  be  lit  continuously. 

This distorts the signal (quickly fatiguing your ears) 
and may damage the speakers.

Normally it is enough just to let the unit cool 

down after you have corrected the problem so that 
the system functions properly again.

The amplifier is provided with a radiator made 

of aluminum which improves heat evacuation.

Keep grilles clean and dust-free.
Do not block or obstruct in any way the air 

entrance or exit while the equipment is in use.

Air circulates from the bottom to the top of the 

amplifier.

Low mains voltage

Therefore  the  current  consumed  by  a  115V 

version is double the 230V version to achieve the 
same acoustic power level.

For 230Vac the consumption of the unit giving 

1/3 of power (with pink noise input signal) is 3A.

If  mains  voltage  falls  below  the  shutdown 

voltage  for  the  unit,  it  will  stop  playing.  When 
acceptable levels are regained, the unit will switch 
back on automatically.

The unit recognised automatically if it´s going to 

work in 230Vac or 115Vac range

The nominal operating ranges are 90V to 125V 

for 115Vac, or 180V to 250V for 230Vac..

Summary of Contents for aero 40A

Page 1: ...zar el equipo lea la sección Precauciones de seguridad de este manual Conserve este manual para futuras consultas Before operating the device please read the Safety precautions section of this manual Retain this manual for future reference ...

Page 2: ...ATIONS RIGGING SYSTEM APPENDIX I APPENDIX II Description ON OFF Overload Indicators Overheating Equalisation Low mains voltage Current consumption CONFIGURATIONS CHANGE OF CONFIGURATION Troubleshooting Line conections unbalanced and balanced DASnet cables SAFETY PRECAUTIONS WARRANTY DECLARATION OF CONFORMITY Manual del Usuario aero 40A User s Manual ...

Page 3: ... the recycling of electrical and electronic equipment El cableado exterior conectado al equipo requiere de su instalación por una persona instruida o el uso de cables flexibles ya preparados The outer wiring connected to the device requires installation by an instructed person or the use of a flexible cable already prepared Si el aparato es conectado permanentemente la instalación eléctrica del ed...

Page 4: ...eparación en garantía es imprescindible que el producto no haya sido previamente manipulado e incluir una fotocopia de la factura de compra All D A S products are warrantied against any manufacturing defect for a period of 2 years from date of purchase The warranty excludes damage from incorrect use of the product All warranty repairs must be exclusively undertaken by the factory or any of its aut...

Page 5: ...65 CE l Directiva RAEE WEEE 2002 96 CE Y es conforme a las siguientes Normas Armonizadas Europeas In accordance with Harmonized European Norms l EN 60065 2002 A11 2008 Audio video and similar electronic apparatus Safety requirements l EN 55103 1 2009 Electromagnetic compatibility Product family standard for audio video audio visual and entertainment lighting control apparatus for professional use ...

Page 6: ...ncy drivers The aero 40A incorporates the latest in digital signal processors Brick wall FIR filters have been used to provide perfect alignment between ways achieving exceptionally uniform coverage all the way down the crossover point Top of the line AD DA converters have been employed allowing for significant improvements in dynamics lower distortion and ultra low noise levels TM Remote monitori...

Page 7: ...0 LINK LINK LINK LINK Example 1 16 aero40A 12 LX 218CA DASnet DASnet DASnet Audio Audio Audio IN IN IN IN IN IN OUT OUT OUT OUT OUT OUT OUT OUT OUT IN IN IN 1 2 3 DASnet DASnet DASnet Audio Audio Audio IN IN IN IN IN IN OUT OUT OUT OUT OUT OUT OUT OUT OUT IN IN IN 1 2 3 L1 L2 L3 I o FI40 30mA 4pol FI Schalter 6 x MCB 16A C 1pol 1 x RCD 40A 30mA 4pol ...

Page 8: ...OUT OUT OUT IN IN IN 1 2 3 DASnet DASnet DASnet Audio Audio Audio IN IN IN IN IN IN OUT OUT OUT OUT OUT OUT OUT OUT OUT IN IN IN 1 2 3 L1 L2 L3 I o FI40 30mA 4pol FI Schalter 6 x MCB 16A C 1pol 1 x RCD 40A 30mA 4pol DASnet DASnet DASnet Audio Audio Audio IN IN IN IN IN IN OUT OUT OUT OUT OUT OUT OUT OUT OUT IN IN IN 1 2 3 DASnet DASnet DASnet Audio Audio Audio IN IN IN IN IN IN OUT OUT OUT OUT OUT...

Page 9: ...ent 138 dB LF 1 x 12GNR GM 12G MF 1 x 8AN4 GM 8AN4 HF 2 x M 75N GM M 75N Trapezoidal 3 5º Birch Plywood Black ISO flex paint Integrated in box design Audio INPUT Female XLR Audio LOOP THRU Male XLR Audio Data INPUT etherCON Audio Data LOOP THRU etherCON AC INPUT powerCON TRUE1 AC OUTPUT powerCON TRUE1 6 0 A 115 V 50 Hz 60Hz 3 0 A 230 V 50 Hz 60Hz 31 5 x 94 2 x 40 cm 12 4 x 37 1 x 15 75 in 68 kg 14...

Page 10: ...o indentify the unit or blink faster if there is TM communication with DASnet 7 SIGNAL LIMIT Two color LED which indicates signal presence if shines green and limiter if shines red 8 AMP PROTECT Red LED which indicates the protection of one or more channels channel is shown on the screen 9 DISPLAY The 2x16 display shows messages or data 10 KEYBOARD Keyboard with 5 buttons for setting or reconfigur...

Page 11: ...ed off Please note that the ON LED can stay on for several seconds after the mains power has been disconnected Overheating This equipment does not normally overheat during normal conditions of use When overheating occurs the unit protects itself You should then find out why and if necessary contact an authorised dealer for technical assistance Equalisation The unit does not need extreme settings o...

Page 12: ...e AC the lighting equipment and the UNIT are connected to the same phase 1 Bad or loose AC connection to the UNIT or the mains outlet 2 Faulty AC cable 3 Internal fuse blown SOLUTION 1 Check that the mixer or sound source is sending signal to the UNIT 2 Check that the cable from the sound source to the UNIT is connected correctly Replace the cable if defective 1 If using a mixer use the balanced o...

Page 13: ...ed of one unit medium shoot and high pass filter off To log in to reconfiguration keep the OK button pushed during two seconds until the arrows cover all the screen We will log in to the menus which allow to change the factory settings Firstly it will appear And pushing the indicated arrows right and left you could log in to other menus To log in just push the OK button In the first menu Configura...

Page 14: ... menu we will find the menu to apply if you wish a high pass filter Cyclically we could come back to any option Push OK to select Remember that high pass filter slopes are 48 dB oct After selecting the number of array units pushing the Up arrow we come back to the previous menu If we push the right arrow now we will log in to the second menu where we select the throw pushing the down arrow 14 ...

Page 15: ...g gain 0 dB and delay 0 ms using the arrows which are shown on the screen keeping OK pushed to select At last appearing on the screen the settings It is very recommendable to restore factory settings after each use and before setting up a new system configuration 15 Manual del Usuario aero 40A User s Manual At last menu if we push right in Utilities menu we will log in to Information ...

Page 16: ...stop You can push OK again and all the information will appear again Note In this example the ID is 02394 Note Firmware version can be updated in the future Note Unit Name can be changed with DASnet Note Gain and Delay can be changed with DASnet Note The screen will switch off in a few seconds 16 Manual del Usuario aero 40A User s Manual ...

Page 17: ...lings and 7 1 for polyester slings Thus an element with a breaking load limit of 1000 kg may be statically loaded with 200 kg 5 1 safety factor and dynamically loaded with 142 kg 7 1 safety factor Accessories aero 40A systems are rigged with the accessories AX AERO40 and PickUp AX AERO40 if you need another lift motor The platform PL 40S allows the transport of four units and PL 40 which is includ...

Page 18: ...et Audio Audio Audio IN IN IN IN IN IN OUT OUT OUT OUT OUT OUT OUT OUT OUT IN IN IN 1 2 3 DASnet DASnet DASnet Audio Audio Audio IN IN IN IN IN IN OUT OUT OUT OUT OUT OUT OUT OUT OUT IN IN IN 1 2 3 DASnet rack 2 patch panels power distro 32Amp American version DASnet rack 2 patch panels power distro 32Amp European version DASnet cables EtherCon cable eC Power Link Shielded STP CAT7 cable Shielded ...

Page 19: ...ed by the shield affects both signal conductors in the same way At the device s input the two signals get summed with opposite sign so that noise is cancelled out while the programme signal doubles in level Most professional audio devices use balanced inputs and outputs Connectors that can carry balanced signal have three pins such as XLR Cannon and 6 35mm stereo The graphs that follow show the re...

Page 20: ...T7 cable These cables are named eCP_xx xx refers to cable length The links between cabinets aero40A Convert15A LX 218CAnet which are STP CAT7 cables Cable code eC_09 Power Links between cabinets Cable code Plink1_09 Links for RoadNet series Power STP CAT7 eCPk_1 eCPk_5 The main feed cable eCP_xx has the following structure AL Shield 2 2 ecP_xx Power cable 3x2 5mm CAT7 4x 2 x 0 14mm Jacket Jacket S...

Page 21: ...88DAS4USA Tel 1 305 436 0521 Fax 1 305 436 0528 D A S AUDIO ASIA PTE LTD 25 Kaki Bukit Crescent 01 00 02 00 Kaki Bukit Techpark 1 Singapore 416256 Tel 65 6742 0151 Fax 65 6742 0157 D A S AUDIO S A C Islas Baleares 24 46988 Fuente del Jarro Valencia SPAIN Tel 96 134 0525 Tel Intl 34 96 134 0860 Fax 96 134 0607 Fax Intl 34 96 134 0607 ...

Reviews: