3-axis accelerometer & 3-axis gyro sensor
MSENS-GY
User’s manual
15
4-8Baudrate of serial
COMMAND
<1 SPEED “VALUE”>
Function
RS485 Baudrate of serial
Value
1, 2, 3
Default
1
Example (SPEED=2)
<1 SPEED 2>
Echo
[1 SPEED 2]
It is setting baudrate of RS485 and check..
Default value is Baudrate:115200, Data bit:8, Stop bit:1, parity:None
SPEED
BAUD RATE
1
115200
2
57600
3
38400
If you wand know what is baudrate value, send <1 SPEED >.
Return value is [1 SPEED 1]. It mean is 115200(baudrate is 115200).
4-9Axis of analog output setting
COMMAND
<1 ANALOG “VALUE”>
Function
Axis of analog output setting
Value
0, 1, 2
Default
2
Example (ANALOG=0)
<1 ANALOG 0>
Echo
[1 ANALOG 0]
It is setting axis of analog output and check.