UMN:CLI
User Manual
V5824G
128
7.1.11.4
Generic Alarm Severity
To set generic alarm severity, use the following command.
Command
Mode
Description
snmp
alarm-severity
admin-access-login
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Global
Sets severity of an alarm for admin-
access-login.
snmp alarm-severity auth-fail
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sets severity of an alarm for auth-fail.
snmp alarm-severity cold-start
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sets severity of an alarm for system
cold restart.
snmp alarm-severity cpu-load-over
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sets severity of an alarm for CPU load
high.
snmp alarm-severity dying-gasp
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sets severity of an alarm when a power
outage of any downstream equipment
occurs with a critical error
snmp alarm-severity ip-conflict
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sets severity of an alarm for IP address
conflict.
snmp alarm-severity memory-over
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sets severity of an alarm for system
memory usage high.
snmp alarm-severity mfgd-block
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sets severity of an alarm for MAC flood
guard block.
snmp alarm-severity port-link-down
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sets severity of an alarm for Ethernet
port link down.
snmp alarm-severity port-link-up
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sets severity of an alarm for Ethernet
port link up.
snmp alarm-severity port-thread-over
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sets severity of an alarm for port
threshold over.
snmp alarm-severity rmon-alarm-rising
{
criti-
cal
|
major
|
minor
|
warning
|
intermediate
}
Sets severity of an alarm for RMON
alarm rising.
snmp alarm-severity rmon-alarm-falling
{
criti-
cal
|
major
|
minor
|
warning
|
intermediate
}
Sets severity of an alarm for RMON
alarm falling.
snmp alarm-severity system-restart
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sets severity of an alarm for system
restart.
To delete configured alarm severity, use the following command.
Command
Mode
Description
no snmp alarm-severity admin-access-login
Global
Deletes configured alarm severity.
no snmp alarm-severity auth-fail
no snmp alarm-severity cold-start
no snmp alarm-severity cpu-load-over
no snmp alarm-severity dying-gasp
no snmp alarm-severity ip-conflict
no snmp alarm-severity memory-over