User Manual
UMN:CLI
V5824G
223
Step 3
If Egress port is Access port (Access port is configured as Untagged), remove SPVLAN. If
egress port is uplink port, transmit as it is.
Step 4
The V5824G switch has 0x8100 TPID value as default and other values are used as
hexadecimal number.
8.1.9.7
Double Tagging Configuration
Step 1
Designate the QinQ port.
Command
Mode
Description
vlan dot1q-tunnel enable
PORTS
Bridge
Configures a qinq port.
PORTS: qinq port to be enabled
Step 2
Configure the same PVID with the VLAN of peer network on the designated qinq port.
Command
Mode
Description
vlan pvid
PORTS
<1-4094>
Bridge
Configure a pvid.
PORTS: qinq port to be enabled
1-4094: PVID
To disable double tagging, use the following command
Command
Mode
Description
vlan dot1q-tunnel disable
PORTS
Bridge
Disables the qinq port.
PORTS: qinq port to be disabled
When you configure Double tagging on the V5824G, consider the below attention list.
•
DT and HTLS cannot be configured at the same time. (If switch should operate as
DT, HTSL has to be disabled.)
•
TPID value of all ports on switch is same.
•
Access Port should be configured as Untagged, and Uplink port as Tagged.
•
Ignore all tag information of port which comes from untagged port (Access Port).
•
Port with DT function should be able to configure Jumbo function also
i