To configure ONU deactivation monitoring, use the following command.
Command
Mode
Description
olt deactive-monitor alarm-raise
<1-99>
GPON-OLT
Sets the deactive ONU-raise percent.
1-99: (default: 30%)
olt
deactive-monitor
alarm-
clear
<1-99>
Sets the deactive ONU-clear percent. If the current
percent becomes higher than this value, the alarm
status changes to off.
1-99: (default: 70%)
olt deactive-monitor period
<10-
86400>
Sets the deactive ONU monitoring period. If the current
percent is higher than a alarm-raise percent, the alarm
is off and the current percent changes to 100% after a
period.
10-86400: deactive ONU monitoring period (default: 10
seconds)
no olt deactive-monitor alarm-
raise
Deletes the configured value of deactive ONU
monitoring parameters.
no olt deactive-monitor alarm-
clear
no olt deactive-monitor period
To display the configuration of ONU deactivation monitoring, use the following command.
Command
Mode
Description
show olt deactive-monitor
[
OLT-
ID
]
Enable
Global
GPON
Shows
the
configuration
of
ONU
deactivation
monitoring.
show olt deactive-monitor
GPON-OLT
To clear the alarms of ONU deactivation monitoring, use the following command.
Command
Mode
Description
clear olt deactive-monitor alarm
GPON-OLT
Clears the collected alarms by ONU deactivation
monitoring.