User Manual
UMN:CLI
V5824G
139
To configure the first alarm to occur when object is firstly more than threshold or less than
threshold, use the following command.
Command
Mode
Description
startup-type rising-and-falling
RMON
Configures the first Alarm to occur when object is firstly
more than threshold or less than threshold.
7.3.2.7
Interval of Sample Inquiry
The interval of sample inquiry means time interval to compare selected sample data with
upper bound of threshold or lower bound of threshold in terns of seconds.
To configure interval of sample inquiry for RMON alarm, use the following command.
Command
Mode
Description
sample-interval
<0-65535>
RMON
Configures interval of sample inquiry.
(unit: second)
7.3.2.8
Activating RMON Alarm
After finishing all configurations, you need to activate RMON alarm. To activate RMON
alarm, use the following command.
Command
Mode
Description
active
RMON
Activates RMON alarm.
7.3.2.9
Deleting Configuration of RMON Alarm
When you need to change a configuration of RMON alarm, you should delete an existing
RMON alarm.
To delete RMON alarm, use the following command.
Command
Mode
Description
no rmon-alarm
<1-65535>
Global
Deletes RMON history of specified number, enter the
value for deleting.
7.3.3
RMON Event
RMON event identifies all operations such as RMON alarm in the switch. You can
configure event or trap message to be sent to SNMP management server when sending
RMON alarm.
You need to open
RMON Event Configuration
mode to configure RMON event.
Command
Mode
Description
rmon-event
<1-65535>
Global
Opens
RMON Event Configuration
mode.
1-65535: index number