UMN:CLI
User Manual
V8102
736
13.1
OLT Management
This section describes how to manage an OLT. The OLT is managed in
GPON Interface
Configuration
mode.
13.1.1
OLT Description
To specify or modify a description of an OLT, use the following command.
Command
Mode
Description
olt description DESCRIPTION
Interface
[GPON]
Registers the OLT
’s description.
no olt description
Deletes the description of OLT.
To display a description of an OLT, use the following command.
Command
Mode
Description
show olt description
[
gpon
OLT-ID
]
Enable/Global
Shows the OLT
’s description.
show olt description
Interface
[GPON]
13.1.2
Activating OLT
To activate/deactivate an OLT, use the following command.
Command
Mode
Description
olt activate
Interface
[GPON]
Activates a specified OLT.
olt deactivate
Deactivates a specified OLT.
13.1.3
Downstream Encryption
This command requires a special request to operate and only available once negotiated.
ONU encryption function is disabled by default.
Encryption of downstream data is automatic process performed by OLT for specified
ONU-IDs configured as encrypted. GPON OLT uses encryption key of the ONU (ONT)
associated with encrypted OLT-ID. To synchronize encryption and decryption keys be-
tween OLT and ONU (ONT), you have to activate the key exchange process. For security
reasons, GPON standard requires periodic key exchange for all active ONUs (ONTs) that
use downstream data traffic.
To enable/disable the encryption mode of downstream traffic, use the following command.
Command
Mode
Description
onu encryption ONU-ID
enable
Interface
[GPON]
Enables the encryption mode.
ONU-ID: ONU ID (1 to 128) or ONU serial number
!