UMN:CLI
User Manual
V8102
124
To display the configured threshold of fan operation, use the following command.
Command
Mode
Description
show status fan
Enable/Global
Shows the status and configured threshold of
fan operation.
6.1.6.4
System Temperature
To set the threshold of system temperature, use the following command.
Command
Mode
Description
threshold temp
HIGH_VALUE
LOW_VALUE
Global
Sets the threshold of system temperature(°C).
HIGH_VALUE: overload system temperature (-40 to
100°C)
LOW_VALUE: underload system temperature (-40 to
100°C)
threshold temp iu NUMBER
HIGH_VALUE LOW_VALUE
Sets the threshold of IU temperature(°C).
NUMBER : a slot number of IU
HIGH_VALUE: overload system temperature (-40 to
100°C)
LOW_VALUE: underload system temperature (-40 to
100°C)
no threshold temp
Deletes the configured threshold of system/IU tempera-
ture.
no threshold temp iu NUMBER
To enable/disable the system/IU shut down due to over-temperature event that can lead
to serious system problems, use the following command.
Command
Mode
Description
threshold
power
iu
SLOT_NUMBER VALUE
Global
Sets the over-temperature threshold value of interface
unit.
VALUE: temperature threshold for IU power-off (60 to
90°C, default: 80°C)
threshold power system VALUE
Sets the over-temperature threshold value of chassis
system.
VALUE: temperature threshold for system shut-down
(80 to 120°C, default: 110°C)
threshold power system
{
ena-
ble
|
disable
}
Enables/disables the system shut down in the over-
temperature event.
no
threshold
power
iu
SLOT_NUMBER
Deletes the configured over-temperature threshold
value of IU/system.
no threshold power system
To display the configured threshold of system temperature, use the following command.