UMN:CLI
User Manual
V8102
166
After configuring upper bound of threshold, configure to generate RMON event when ob-
ject is more than configured threshold. Use the following command.
Command
Mode
Description
rising-event
<1-65535>
RMON
Configures to generate RMON event when object is
more than configured threshold.
1-65535: event index
7.3.2.5
Lower Bound of Threshold
If you need to occur alarm when object used for sample inquiry is less than lower bound
of threshold, you should configure lower bound of threshold.
To configure lower bound of threshold, use the following command.
Command
Mode
Description
falling-threshold
VALUE
RMON
Configures lower bound of threshold.
After configuring lower bound of threshold, configure to generate RMON event when ob-
ject is less than configured threshold. Use the following command.
Command
Mode
Description
falling-event
<1-65535>
RMON
Configures to generate RMON alarm when object is
less than configured threshold.
7.3.2.6
Standard of the First Alarm
It is possible for users to configure standard when alarm is first occurred. User can select
the first point when object is more than threshold, or the first point when object is less
than threshold, or the first point when object is more than threshold or less than threshold.
To configure the first RMON alarm to occur when object is less than lower bound of
threshold first, use the following command.
Command
Mode
Description
startup-type falling
RMON
Configures the first RMON Alarm to occur when object
is less than lower bound of threshold first.
To configure the first alarm to occur when object is firstly more than upper bound of
threshold, use the following command.
Command
Mode
Description
startup-type rising
RMON
Configures the first Alarm to occur when object is firstly
more than upper bound of threshold.