UMN:CLI
User Manual
V8102
216
To forcefully change to the blocking state of the master node
’s uplink port, use the follow-
ing command.
Command
Mode
Description
ethernet oam uplink-redundancy
meg NAME
forced-switch
Global
Allows the operator to forcefully block the uplink port of
master node. If the link failure occurs on the uplink port
of slave node, both uplink ports of slave and mater
node are blocked.
no
ethernet
oam
uplink-
redundancy meg NAME forced-
switch
Cancels an existing forced-switch command on the
uplink port.
7.7.20.3
Control VLAN
For uplink redundancy operation, there are one master node and the other slave node. To
communicate each other, it needs to transmit the control packets through the control
VLAN ID.
To enable/disable a control VLAN ID for communication between a master node and
slave node, use the following command.
Command
Mode
Description
ethernet oam uplink-redundancy
meg NAME control-vlan VLAN
Global
Specifies a control VLAN ID.
no
ethernet
oam
uplink-
redundancy meg NAME control-
vlan
Deletes the configured control VLAN ID.
7.7.20.4
Ring Topology Monitoring
The V8102 provides uplink redundancy feature with G.8032 (ERPS) ring topology. If the
communication between the master and slave node is not available because of the inter-
nal error of ring, the uplink ports of master/slave node should be changed to the forward-
ing state. To monitor the connectivity of ring ports via OAM CCM, use the following com-
mand.
Command
Mode
Description
ethernet oam uplink-redundancy
meg NAME
cc meg NAME
primary-mepid
<1-8191>
Global
Enables a single ring port to monitor connectivity be-
tween uplink ports of the master and slave node using
OAM CCM.
ethernet oam uplink-redundancy
meg NAME
cc meg NAME
secondary-mepid
<1-8191>
Enables two ring ports to monitor connectivity between
uplink ports of the master and slave node using OAM
CCM.
no
ethernet
oam
uplink-
redundancy meg NAME cc meg
NAME primary-mepid
Disables a single ring port to monitor connectivity be-
tween uplink ports of the master and slave node using
OAM CCM.
no
ethernet
oam
uplink-
redundancy meg NAME cc meg
NAME secondary-mepid
Disables two ring ports to monitor connectivity between
uplink ports of the master and slave node using OAM
CCM.