background image

 

3

 

 

1. Safety Precautions 
 
1.1 Basics

 

   

 

l

 

 

Following these safety precautions will ensure the safe and proper use of the 

product and help prevent accidents and minimize hazards. 

 

l

 

 

The various symbols along with their meanings used in the User and Installation 

Guide and on the product itself are shown below.

 

 

Warning against risks under certain conditions.

 

 

Warning regarding risks of electric shock possible under certain conditions. 

 

 

l

 

 

Safety Precaution is divided into two categories: 'Warning' and 'Caution'.   

  The following:

 

 

            Warning : 

Failure to follow instructions can result in serious injury or death.

 

            Caution  : 

Failure  to  follow  instructions  can  lead  to  a  minor  injury  or  product 

damage.

 

 

l

 

 

After reading the Instructions for Use and Installation, keep it in a place where 

the user can see them at any time. 

l

 

Please familiarize yourself with the information in this manual to understand the 

functions of Soleaf Air and safety. 
 

 
 

 

Summary of Contents for Soleaf Air DSR-004-OD

Page 1: ...Soleaf Air DASS Wi Fi CM 04A001e DSR 004 OD Version 1 1 User Manual ...

Page 2: ... 2 2 Product Appearance 5 2 3 Product Check 5 2 4 Product Composition 6 2 5 Product Dimensions 8 3 Installation 8 3 1 Transportation 8 3 2 Place of Installation 9 3 3 Installation Precautions 9 3 4 Installation Precautions 10 3 5 Precautions for Wiring 11 3 6 SETUP Method 15 4 Product Specifications 17 5 Warranty 18 ...

Page 3: ...ing regarding risks of electric shock possible under certain conditions l Safety Precaution is divided into two categories Warning and Caution The following Warning Failure to follow instructions can result in serious injury or death Caution Failure to follow instructions can lead to a minor injury or product damage l After reading the Instructions for Use and Installation keep it in a place where...

Page 4: ...e the terminal causing electric shock Do not use the wire when it is damaged It may cause electric shock Do not place heavy objects on the wire Damage to the wire sheath can cause electric shock Do not input power even if installation is complete on terminals with damaged parts It may cause electric shock Caution Do not install near flammable materials Installation on or near flammable materials m...

Page 5: ...n port specified for that device with the RS485 interface Device information collected from the Soleaf Air can be sent to a web server or local server via the RS485 interface to monitor solar energy integrated generation information in real time or to retrieve historical information stored on the server Plant information and account information required for server account setup and Soleaf Air sett...

Page 6: ...vice from the box check the nameplate on the side of the body and see if the device format matches the product ordered Also make sure that there is no damage made during transport Terminal TYPE Symbol DSR Name DASS RTU Symbol 4 Group Name 004 Series Symbol OD Group Name External Internal ...

Page 7: ...D blocks antenna and USB wires The preparations for operation vary depending on the installation site so prepare the parts as necessary Example Multi Tester for voltage and wiring checkup power tools for installation and fixing etc 2 4 Product Composition l Front view Figure 3 Front view of product LNK STA PWR status light indicator ...

Page 8: ... Upper view of product Antenna and Inverter Connections Mainboard communication port and connector composition 1 Number Description Antenna 4 pin Connector Emulator connector Reset Switch RS485 and power cord USB connector ...

Page 9: ...m d 3 Installation 3 1 Transportation Please transport by proper means according to product weight Please check external conditions Do not pile up beyond the limited level or height Do not open the cover while being transported Do not drop or cause damage with shock ...

Page 10: ...xists Install in a location where the Wi Fi signal is highly sensitive Poor Wi Fi signal sensitivity will prevent smooth communication Check sensitivity using Wi Fi sensitivity measurement application Avoid places with low signal sensitivity such as walls or enclosures 3 3 Installation Precautions l Follow the instructions in this operation and installation manual l This product may be installed i...

Page 11: ...lock nut specification is M4 35 see Figure 2 2 Insert the nut into the machined hole and attach it firmly using a tool such as a hammer 3 Attach the bolt to the attached nut Here do not fully attach but remain 3 to 4 mm from the wall see Figure 1 4 Attach the product to the bolt and press lightly in vertical downward direction to fix it See Figures 2 3 5 If the product is loosely attached or diffi...

Page 12: ...er source inside the inverter for power If it is not properly connected the wires must be carefully routed as this may malfunction or damage the Soleaf Air Connect the inverter system connection board RS485 connector to fit the hole l Install the Soleaf air before wiring connector connection l Turn on the inverter power to the ON state after the wiring is complete and before closing the cover l Wh...

Page 13: ...erial communication As communication between devices may be abnormal if the termination resistance is not handled or handled incorrectly to enable termination resistance on the appropriate device referring to the diagram below Since the serial communication termination resistance process may vary by inverter models refer to the corresponding inverter manual for details on how to set it up If more ...

Page 14: ...ere is a connection between the Soleaf Air and the inverter etc l If the Power Status Indicator is off make sure that the inverter that supplies power to the Soleaf Air is not turned off If the external switch and power supply are proper functioning the Soleaf air internal switch may be switched off In this case contact your monitoring maintenance specialist l If the STA Status Indicator flashes i...

Page 15: ...15 l 4 pin Connector Line Color Description Red 5V Black GND White Data Yellow Data Num ber Description 1 Data 2 Data 3 5V 4 GND ...

Page 16: ...respectively and run the ezsetup file 2 Select the PORT associated with your PC and OPEN only the red light will be displayed if you enter setup mode later 3 Click READ to confirm the response Always press READ or WRITE to confirm that the LOG RAW DATA responds with RX ...

Page 17: ...sing static IP select address allocation manually and enter IP NETMASK GATEWAY DNS and WRITE 5 Click on the inverter or system interface at the top READ click ID enter model name WRITE The system access panel ID must be the same as the corresponding Inverter ID 6 When all settings are complete press CLOSE and exit ezsetup ...

Page 18: ...WIFI Connector For JSN270IF Debug Port USB serial mini USB 1x3 2 54mm pin header UART NB IOT Connector 1x13 1 27mm pin header socket RIGHT LED 3 POWER STATUS LINK LED Status Color POWER Red STATUS LINK Green RS485 Non isolated Half duplex Max 1Mbps JTAG Connector 2x7 2 54mm pin header POWER and Usage Environment 5V 1A input voltage range 4 5V 5 5V PBA Size 50mm x 90mm Dimensions 93mm x 73mm x 31 5...

Page 19: ...d under normal using condition within the warranty period your product can be tested and repaired for free Charged A S For following cases A S could be provided at a cost The product is out of order due to the customer s intention or carelessness The product is out of order due to failure in connected devices by error of applied power supply Any failure due to natural cause In case the product was...

Page 20: ...20 M E M O ...

Page 21: ...oduct s specifications are subject to change without notice for example quality improvement Please contact when you purchase a product DASS TECH CO LTD 81 Yangcheongsongdae gil Ochang eup Cheongwon gu Cheongju si Chungcheongbuk do 28118 Korea Tel 82 43 218 5670 Fax 82 43 818 5671 http www dasstech com Ver 1 1 ...

Reviews: