background image

CHAPTER 3 : FRONT PANEL AND MENU TREE 

profile#0,and flush the stored telephone numbers. 

Are you sure??? 

 

/confirm  the  initializing action. Press enter key to 
confirm or any other key to quit. 

 

 

 

Serg edit 

ATSn=m 

Edit the contain of the selected sreg. 

Base = DEC 

 

/Edit the value of the S-register in decimal form. 

Base = Bin 

 

/Edit the value of the S-register in binary form. 
After selecting the form, press Enter to starting 
editing S-register shown in the following format. 

 

 

 

XX : 

△△△□□□□□□□□

 

 

xx: Use left key,right key and enter key to select 
the S-register to be edited. 

 

 

∆∆∆

: Use left key, right key and enter key to edit 

the value of the selected S-register in decimal 
form. 

 

 

……………………

: Use lift, right, and enter key to 

edit the value of the selected S-register in binary 
form. 

 

 

 

 

 

To discard editing, press exit key. 

 

35 

Summary of Contents for V.3600UI

Page 1: ...DataConnect V 3600UI modem User Manual V1 7 07008 00027 2004 11 15...

Page 2: ...U 27 3 5 5 CONFIG MODEM MENU 28 3 5 6 CONFIG DTE MENU 30 3 5 7 COMMAND MENU 32 3 5 8 LINE SETUP MENU 33 3 5 9 PROFILE MENU 34 CHAPTER 4 GENERAL INFORMATION AND FEATURES 38 4 1 Preview 38 4 2 Dial Line...

Page 3: ...7 5 2 Dial Modifiers 53 5 3 Result Codes 54 5 4 V 25bis Auto call Unit 56 CHAPTER 6 MAINTENANCE 58 6 1 Description 58 6 2 Instruments 58 6 3 Periodic Maintenance 58 6 4 Troubleshooting 58 6 5 Return P...

Page 4: ...y turning the equipment off and on The user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation...

Page 5: ...telephone network the telephone company may discontinue your service temporarily If possible they will notify you in advance But the advance notice isn t practical you will be notified as soon as poss...

Page 6: ...CHAPTER 1 MODEM INTRODUCTION Chapter 1 MODEM INTRODUCTION 1 1 Description 1 2 Technical Specifications 1 3 Ordering Information 1...

Page 7: ...ive Precoding Non Linear Encoding Warping Constellation Expansion Multidimensional Trellis coding and Shell Mapping Tx power back off Power Reduction There are 10 factory default profiles and 10 user...

Page 8: ...eed range 2 3 to 2 5 DTE speed 1 Synchronous 33600 31200 28800 26400 24000 21600 19200 16800 14400 12000 9600 7200 4800 2400 1200 bps 2 Asynchronous 115200 76800 57600 38400 33600 32000 31200 28800 26...

Page 9: ...le 1 1c 4 to 1024 Depends on the combination of data rate symbol rate and constellation expansion chosen V 32bis 14400 T TCM 1800 2400 128 V 32bis 12000 T TCM 1800 2400 64 V 32 9600 T TCM 1800 2400 32...

Page 10: ...120 mA Holding Resistance 50 220 Holding Current 25 110 mA Ring Detect Range ON 27 Vrms OFF 13 Vrms Ring Detect Frequency 16 50 Hz DTMF Characteristics O P Lowband 8 1 dBm O P Highband 6 1 dBm Frequen...

Page 11: ...Physical Size Stand alone W 180mm H 48mm D 262mm Weight 0 9kg Rack mount card W 220mm H 26mm D 328mm Weight 0 6kg Rack mount shelf W 19 H 6RU D 380mm Weight 8kg Full shelf Equipped Weight 16kg DTE Int...

Page 12: ...CHAPTER 1 MODEM INTRODUCTION 7...

Page 13: ......

Page 14: ...ATION C H A P T E R 2 I N S T A L L A T I O N 2 1 Description 2 2 Unpacking 2 3 Site Requirements 2 4 Site Selection 2 5 AC Electrical Outlet Connection 2 6 Connecting With Dial Line 2 7 Connecting Wi...

Page 15: ...ilure after you unpack the modem check carefully for shipping damage Contact the shipper if you notice any damage Direct any additional questions about damaged or missing parts to the nearest sales re...

Page 16: ...k Series Modem no farther than 50 feet 15 24 meters from your data terminal equipment DTE and within 6 feet 1 83 meters of a grounded AC outlet furnishing the required power Install the modem in a cle...

Page 17: ...E jack The pin layout of the PHONE connector for RJ11 operation is as follows Pin Color PHONE pin defined 1 No Connect No Connect 2 Black Not used 3 Red Tip 4 Green Ring 5 Yellow Not used 6 No Connect...

Page 18: ...d line application Pin 7 8 is another group it is no used in 2 wire leased line application it is RX for 4 wires leased line application When it used RJ 11 4 core wire pin 4 5 is TX RX for 2 wire leas...

Page 19: ......

Page 20: ...AND MENU TREE C H A P T E R 3 FRONT PANEL AND MENU TREE 3 1 The Front Panel Description 3 2 The Rear Panel Description 3 3 Operating the Network Series Modem 3 4 The Menu Tree 3 5 Detailed Descriptio...

Page 21: ...the configurations as illustrated below Figure 3 1 Front Panel 3 2 The Rear Panel Description The rear panel of modem contains an IEC 320 AC Power Inlet Connector a Power On Off switch a RS 232 conne...

Page 22: ...ower supply ok DTR On for DTR signal present DSR On for DSR signal present RTS On for RTS signal present CTS On for CTS signal present TXD On for 0 off for 1 TXD signal present DCD On for received car...

Page 23: ...from this menu 7 Note that status menu is not available before connection C Menu Screen Exp 1 Exp 2 L STATUS RX Level 10dBm R CONFIG MODEM TX clock Exp 3 Exp 4 L TEST LAL ON L DIAL Dial a number Desc...

Page 24: ...Bm S N Ratio XX dB EQM Valueio XXX F Shift X X Hz F F Shift X X Hz Delay XXXX ms P jitter X Deg STATUS F Echo XX X dB DTE XXXXX ASY 10 Retrains XXXXX RX Speed XXXX TX Speed XXXX RX Baud XXXX TX Baud X...

Page 25: ...MNP MNP Normal Discon Method Immediate With Clear down Modem Reset Login Check Disable 0 9 ALL By NMS Send Password Off 0 9 CallBack No 0 9 CallBack Timer Disable 1 255 Seconds Connect Code DTE Speed...

Page 26: ...bps 38400bps 33600 bps 31200bps 32000bps 28800 bps 26400 bps 24000 bps 21600 bps 19200 bps 16800 bps 14400 bps 12000 bps 9600 bps 7200bps 4800 bps 3600 bps 2400 bps 1800 bps 1200 bps 600 bps 300 bps...

Page 27: ...2 96Q V32 96T V32b 72 V32 48 V26b 2400 V26b 1200 V23 1200 V22b 2400 V22 1200 BELL 212A BELL 103 V21 300 Dial To Leased Manul Auto Dial To Leased Timer Forver 0 255 Minutes Dial to Dail Off On I PROFIL...

Page 28: ...HIFT XX Hz AT S Frequency shift offset It is the shift of the carrier central frequency caused by the transmission link This shift normally should be less than 7 Hz The smaller is better F F SHIFT XX...

Page 29: ...requency of received signal For examples RX Freq 1959Hz means the unique frequency used to to carry data is 1959 Hz This value is only available when operating on V 34 TX FREQ XXXXHz AT S Indication o...

Page 30: ...ne ATXn Enable detecting of busy tone or dial tone to proceed dialing and showing the connection Basic ATX0 Don t care any tone and do not show line connection speed Don t Care ATX1 Don t care any ton...

Page 31: ...DCE speed Discon method ATS28 n Disconnect method for V34 V32bis V32 Immediate bit3 2 Disconnect immediately With clear down Send clear down sequence before disconnection default Modem reset Reset mo...

Page 32: ...ction 3 5 4 TEST MENU Item Name Command Description Clear All AT T0 Clear all the tests in one time and a statement Has been done shall be shown LAL ON OFF AT T1 Local analog loop test ON OFF This tes...

Page 33: ...120 AT B19 Set modem speed to V 32bis 12000 bps TCM V32 96Q AT B18 Set modem speed to V 32 9600 bps QAM V32 96T AT B17 Set modem speed to V 32 9600 bps TCM V32b 72T AT B16 Set modem speed to V 32bis...

Page 34: ...By DTR function Off disable the OH By DTR function default RTRN Threshold ATS57 n bit1 0 Select the scaleable retrain threshold for determining the data rate of the connection High Issue a retrain or...

Page 35: ...nction can detect all the listed DTE speed Default 57600 bps Flow Control AT Qn Used to set flow control between terminal and modem when using V 42 MNP and normal mode asynchronous mode only Off AT Q0...

Page 36: ...TU T V 13 standard simulated carrier in half duplex mode V 23 HDX AT C2 ITU T V 23 standard simulated carrier in half duplex mode RTS Control AT Rn RTS signal control selection Normal AT R0 Controlled...

Page 37: ...he terminal against any malfunction caused by the return result code from the modem Auto Baud AT Un Auto baud rate detection function control for AT command mode On AT U1 Enable default Off AT U0 Disa...

Page 38: ...r group Backup Speed ATS55 n Select modem speed used in the auto dial backup mode V34 Adapt to V21 300 default V 34 288 Dial To Leased ATS31 n Select whether return to leased line automatically or not...

Page 39: ...icable to the most of the Sync 2 wire leased line 6 SY 2L ORG V34 AT F6 W Sync 2W leased line originate applicable to the most of the Sync 2 wire leased line 7 SY 4L ANS V34 AT F7 W Sync 4W leased ans...

Page 40: ...r in decimal form Base Bin Edit the value of the S register in binary form After selecting the form press Enter to starting editing S register shown in the following format XX xx Use left key right ke...

Page 41: ......

Page 42: ...rrection And Data Compression 4 7 Configuration Profile Set up 4 8 Remote Access 4 9 Multi standard Handshake 4 10 Auto Dial Back Up 4 11 Auto Fallback And Fall Forward 4 12 Line Status Monitoring 4 1...

Page 43: ...y and higher reliability DTE MODEM MODEM DTE FIG 4 1 Leased Line B B Before using a dial line such as the circuits for telephone and facsimile machine we have to dial a number For the users who are us...

Page 44: ...eased Line 4W Leased Line FIG 4 3 2W 4W leased line 4 4 Answer Mode VS Originate Mode While using the dial line there must be a modem initiating the call once the exchange recognizes the number it con...

Page 45: ...Correction and Data Compression while operating in asynchronous mode In addition to 100 error free it also provides two to four times data compression rate to increase throughput MNP class 4 provides...

Page 46: ...1 1 1 1 1 MODEM SPD V 34 Adapt V 34 Adapt V 34 Adapt V 34 288 V 34 288 V 34 288 V 34 288 V 34 288 V 34 288 V 34 288 ORG ANS ANS ANS ANS ANS ORG ANS ORG ANS ORG ANS Tx level 13dBm 13dBm 13dBm 13dBm 13d...

Page 47: ...ble data rate is always select with minimal interruption to user data To use this function the FF FB control under CONFIG MODEM menu must set to be on 4 12 Line Status Monitoring In order to let users...

Page 48: ...To start it activate RDL in Test menu then execute BER test stated above Beware that error codes generated by local modem will be received by itself Hence the error count you get is the sum of that of...

Page 49: ...code overrides the setting of Call Back No in ORG modem If Send Password Off on ORG modem or Call Back No Disable this character will be ignored 4 17 2 Extension Code for Stored Phone Numbers char If...

Page 50: ...if user has set Dial To Dial function to On then the dialing will keep dialing 2 Also reminds that a If user is using ATDTxxxx command to dial then it will start the dial polling from Telephone Numbe...

Page 51: ...CHAPTER 5 INSTRUCTION SETS CHAPTER 5 INSTRUCTION SETS CONTENT 5 1 AT Command Set 5 2 Dial Modifiers 5 3 Result Codes 5 4 V 25bis Auto Call Unit 46...

Page 52: ...on hook 1 off hook ATIn modem identification command 0 report product code 1 ROM checksum 2 verify ROM checksum 3 Report ROM components 4 modem capabilities and version 5 Country Code 6 pump controlle...

Page 53: ...peed ATXn result code formats call progress options 0 CONNECT without speed message blind dial no busy tone 1 CONNECT with speed message blind dial no busy tone 2 CONNECT with speed message wait for d...

Page 54: ...1 sync data mode AT Pn dial pulse MAKE BREAK ratio 0 USA 39 61 1 UK 33 67 AT Rn RTS CTS options 0 RTS normal 1 RTS forced on AT Sn DSR control 0 DSR forced on 1 DSR on after connect AT Tn selftest com...

Page 55: ...T Zn string store the string to tel number n AT Jn DTE DCE speed convert on off 0 enable DTE DCE speed convert 1 disable DTE DCE speed convert AT Nn protocol type options 0 normal mode 1 driret mode 2...

Page 56: ...15 V32_4800 16 V32b_7200 17 V32_9600T 18 V32_9600Q 19 V32b_12000 20 V32b_14000 26 V34_19200 27 V34_24000 28 V34_28800 29 V32t_16800 30 V32t_19200 31 V34_4800 32 V34_7200 33 V34_9600 34 V34_14400 35 V...

Page 57: ...e AT Sn display current line status 0 display local status 1 display remote status AT Gn auto fall forward fallback enable 0 auto fall forward fallback disable 1 auto fall forward fall back enable AT...

Page 58: ...able tone dial P or p enable pulse dial 0 to 9 A to D a to d dial digit pause flash hook W or w or wait for dial tone return to idle after dial or wait for quiet answer silence intelligent dial pollin...

Page 59: ...RING 3 NO CARRIER 4 ERROR 5 CONNECT 1200 6 NO DIAL TONE 7 BUSY 8 NO ANSWER TONE 9 None 10 CONNECT 300 11 CONNECT 600 12 None 13 CONNECT 1800 14 CONNECT 2400 15 CONNECT 3600 16 CONNECT 4800 17 CONNECT...

Page 60: ...SETS Table 5 3 Result Codes cont Short Long form 24 CONNECT 24000 25 CONNECT 26400 26 CONNECT 28800 27 CONNECT 32000 28 CONNECT 38400 29 CONNECT 57600 30 CONNECT 76800 31 CONNECT 115200 32 CONNECT 312...

Page 61: ...ry address y y 0 9 d RLN Request list of all stored numbers e CIC Connect incoming call Auto answer enable f DIC Disregard incoming call Auto answer disable 2 V 25bis Responses a INC Modem detects an...

Page 62: ...CHAPTER 6 MAINTENANCE CHAPTER 6 MAINTENANCE CONTENT 6 1 Description 6 2 Instruments 6 3 Periodic Maintenance 6 4 Troubleshooting 6 5 Return Procedure 57...

Page 63: ...e the IC s on printed circuit board are firmly sited Try to turn the power on again if the trouble still exists please follow the procedures below 1 Power Unit Make sure you get a proper power source...

Page 64: ...00 ms Guard Time Escape Sequence Pause S13 19 binary Bit Mapped Options set clear bit 4 3 2 1 0 DTE Speed 0 300 bps 1 600 bps 2 1200 bps 3 1800 bps 4 2400 bps 5 3600 bps 7 7200 bps 8 9600 bps 9 12000...

Page 65: ...rved bit 2 1 NRZ 0 NRZI bit 3 1 flag idle 0 mark idle bit 5 4 word length 00 7 bit data even parity 1 stop bit 01 8 bit data no parity 1 stop bit 10 7 bit data odd parity 1 stop bit 11 7 bit data no p...

Page 66: ...ATX4 CONNECT with speed message wait for dial tone check busy tone Dial Busy Tone bit 7 0 AT P0 Make Break ration USA 39 1 AT P1 Make break ratio UK 33 3 S23 00100001 binary Bit Mapped Options set cle...

Page 67: ...ved bit 7 6 line type 00 AT L0 dial line 01 AT L1 2 wired leased line 10 AT L2 4 wired leased line 11 reserved S28 00000000 binary Bit Mapped Options bit 0 1 2 to 35 dBm receive dynamic range 0 12 to...

Page 68: ...Second S38 00000000 binary V34 Baud Rate Selection bit 0 enable 2400 disable 2400 bit 1 reserved this bit always must be set bit 2 enable 2800 disable 2800 bit 3 enable 3000 disable 3000 bit 4 enable...

Page 69: ...erved S49 Reserved S50 00000000 binary Bit Mapped Options bit 1 0 FAX DATA Mode Selection 00 DATA mode 01 reserved 10 reserved 11 reserved bit 2 reserved bit 7 6 5 4 3 reserved S51 00000011 binary Bit...

Page 70: ...mal mode 0010 AT N2 MNP reliable mode 0011 AT N3 auto reliable mode 0100 AT N4 LAPM reliable No Default Unit Function Description 0101 AT N5 LAPM reliable with fallback to normal mode 0110 AT N6 LAPM...

Page 71: ...1 S REGISTER TABLE 01 medium 11 reserved S59 0 10 Low bit 2 reserved bit 3 Security password pass through bit 7 6 5 4 reserved S58 Retrain times 0 255 default 2 Profile Checksum S60 decimal Power up...

Page 72: ...p ORG ANS Mode Flow Control Auto Baud I S N Ratio Ring Times Login Check DL Auto Retrain Initial DTR Off Action Framing Backup Tel EQM Progress Tone Send password RDL Tx Clock DTR Control Async form B...

Page 73: ...Dial Tone Dial Backup Card Fail 01Select Menu Ararm Config 01 Alarm Config Group Setup 01 Group Setup XXXXXXXXXXXXXXXX RXL Low RXL High SNR Bad Chk Dial Line Dial Backup DTR Off TD RD Inactive N Echo...

Reviews: