Running a Job on PSV5000 ■ List of Steps to Start a Job
- 40 -
Data I/O ■ 096-0466-001E
2.
Now select the appropriate
Probe Tip
(based on your selection of the
optimal nozzle in Step 1). All of the tips have only 1 of 2 different
mounting squares: 1.9 or 2.7 mm.
Part Number
Probe Tips
Square Size
(mm)
6460171001
HOLDER, RUBBER TIP,1.9MM SQUARE,PSV
1.9
6460172001
HOLDER,LARGE RUBBER TIP,2.7 MM SQUARE,PSV
2.7
6460171001 (ProbeTip 1.9mm Square)
6460172001 (ProbeTip 2.7mm Square)
Figure 40:
Different-sized probe tips.
3.
Lastly, select the appropriate
Probe
(Tip Holder) for your device.
Probes
6150321002
ASSY,CLIPLESS TIP HOLDER,PNP,PSV
Removing and Installing the Probe
CAUTION:
Safety hazard! Possible personal injury from moving
machinery. Always make sure that the PNP head is stopped in the
Park
or
Tool
position before opening any access doors.
1.
Pause or Finish a job if one is running.
2.
At the Gantry window, click the Tool position to move the head to the Tool
position for easy access.