■ List of Steps to Start a Job
≡
Running the Automatic Tray Feeder
PSV5000 Operator’s Manual
- 49 -
5.
If you see the confirmation dialog box about overwriting previous values,
click
Yes
to continue.
6.
Now click
X,Y AutoFind
.
Figure 53:
Click ‘X,Y AutoFind’ to teach the horizontal position.
7.
If you see another confirmation dialog box about overwriting previous
values, click
Yes
to continue.
8.
Near the bottom-middle section of the Gantry window, click
Save
.
9.
Now click the
Trays
tab, set the
Dimensions
for Tray 1 (number of devices
per column and row), and then click the Diagonal Corner button.
Figure 54:
Setting the dimensions for your specific tray/device.