Maintenance ■ Pick and Place Probe
- 112 -
Data I/O ■ 096-0465-001C
Figure 67:
Two of the four grease ducts on the rear linear guide of
the gantry.
Note:
Too much grease may cause grease to splatter inside the work
envelope. Do not over-apply the grease.
9.
Lubricate the rear ball screw after wiping off the old grease. Directly
apply new grease to the ball screw sparingly. Wipe off any excess.
10.
Open the front safety doors and remove the four screws securing the
front guard of the front linear guide of the gantry (2 mm hex key).
11.
Remove the screw covering the grease duct.
12.
Apply grease to the grease duct on each end of the slide block. Wipe
off any excess. See figure below.