Pick and Place Probe
Inspecting Gantry Parts
PSV5000 Owner’s Manual
- 113 -
Figure 68:
One of the two front gantry rail lube ducts. Note that the
guard has already been removed.
10.
Lubricate the front ball screw after wiping off the old grease. Directly
apply new grease to the ball screw sparingly. Wipe off any excess.
11.
Replace all screws, guards, and shields.
G
ANTRY
Y-
AXIS
L
UBRICATION
1.
Open the front and rear safety doors and remove the four screws
securing the guard of the Y-axis linear guide (2 mm hex key).
2.
Slide the guard out from either the front or back after pulling slightly
to clear the end cap.